Dissolved inorganic carbon (DIC), alkalinity, pH, chlorofluorocarbons, temperature, salinity, oxygen, nutrients, and other measurements collected from discrete samples and profile observations during the R/V Ryofu Maru III cruise rf201805 (EXPOCODE 49UP20180614) in the North Pacific Ocean from 2018-06-14 to 2018-07-22 (NCEI Accession 0209264)
PACKAGE DESCRIPTION: This dataset includes discrete profile measurements of dissolved inorganic carbon (DIC), total alkalinity, pH on total scale, chlorofluorocarbon-11 (CFC-11), chlorofluorocarbon-12 (CFC-12), chlorofluorocarbon-113 (CFC113), temperature, salinity, oxygen, nutrients and other measurements collected from discrete samples and profile observations during the R/V Ryofu Maru III cruise rf201805 (EXPOCODE 49UP20180614) in the North Pacific Ocean from 2018-06-14 to 2018-07-22.
CITE AS: Sakurai, Keizo; Nara, Chikara; Ishii, Masao (2020). Dissolved inorganic carbon (DIC), alkalinity, pH, chlorofluorocarbons, temperature, salinity, oxygen, nutrients, and other measurements collected from discrete samples and profile observations during the R/V Ryofu Maru III cruise rf201805 (EXPOCODE 49UP20180614) in the North Pacific Ocean from 2018-06-14 to 2018-07-22 (NCEI Accession 0209264). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.25921/vzkj-kr87. Accessed [date].
Discrete measurement;Profile;
TEMPORAL COVERAGE:
SPATIAL COVERAGE:
GEOGRAPHIC NAMES:
PLATFORMS:
RESEARCH PROJECT(S):
VARIABLES / PARAMETERS:
Dissolved Inorganic Carbon | |
---|---|
Abbreviation: | TCARBN |
Unit: | UMOL/KG |
Observation type: | discrete |
In-situ / Manipulation / Response variable: | In-situ observation |
Measured or calculated: | Measured |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Total Alkalinity | |
---|---|
Abbreviation: | ALKALI |
Unit: | UMOL/KG |
Observation type: | discrete |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
pH on total scale | |
---|---|
Abbreviation: | PH_TOT |
Observation type: | discrete |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
CTD Temperature | |
---|---|
Abbreviation: | CTDTMP |
Unit: | degrees celcius |
Observation type: | CTD sensor |
Sampling instrument: | CTD |
Analyzing instrument: | CTD Sensor |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
CTD Salinity | |
---|---|
Abbreviation: | CTDSAL |
Observation type: | CTD sensor |
Sampling instrument: | CTD |
Analyzing instrument: | CTD sensor |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
CTD Dissolved Oxygen | |
---|---|
Abbreviation: | CTDOXY |
Unit: | UMOL/KG |
Observation type: | CTD, profile |
Sampling instrument: | CTD |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Salinity | |
---|---|
Abbreviation: | SALNTY |
Observation type: | Discrete, bottle |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
Dissolved Oxygen | |
---|---|
Abbreviation: | OXYGEN |
Unit: | UMOL/KG |
Observation type: | Discrete, bottle |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
silicate, nitrat, nitrit, phosphate | |
---|---|
Abbreviation: | Nutrients |
Unit: | UMOL/KG |
Observation type: | Discrete, bottle |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
CFC-11, CFC-12, CFC113 | |
---|---|
Abbreviation: | Chlorofluorocarbon-11, Chlorofluorocarbon-12, Chlorofluorocarbon-113 |
Unit: | PMOL/KG |
Observation type: | Discrete, bottle |
Sampling instrument: | Niskin Bottles |
Quality flag convention: | WOCE quality control flags are used: 2 = good value, 3 = questionable value, 4 = bad value |
SUBMITTED BY: Robert M. Key (key@princeton.edu)
SUBMISSION DATE: 2020-03-10