N isotopic composition of Phenylalanine and Glutamic Acid from a number of organisms, demonstrating new HPLC protocol for precise isotopic measurements on 2017-08-02 (NCEI Accession 0292208)

browse graphicGraphic not available.
This dataset contains biological and chemical data collectedat California Margin , Santa Barbara Basin , CA current system, Eastern Tropical Pacific on 2017-08-02. These data include amino acid concentration and amino acid name. The instruments used to collect these data include Elemental Analyzer, Gas Chromatograph, High Performance Liquid Chromatograph, and Isotope-ratio Mass Spectrometer. These data were collected by Matthew D. McCarthy of University of California-Santa Cruz as part of the "The Use of Nitrogen Isotopes of Amino Acids To Understand Marine Sedimentary 15N Records (Amino Acid Sediment 15N)" project. The Biological and Chemical Oceanography Data Management Office (BCO-DMO) submitted these data to NCEI on 2019-08-02.

The following is the text of the dataset description provided by BCO-DMO:

N isotopic composition of Phenylalanine and Glutamic Acid from a number of organisms

Dataset Description:
N isotopic composition of Phenylalanine and Glutamic Acid from a number of organisms.

These data were published in:
Broek, T, and McCarthy, M.D. (2014) A New Approach to ä 15 N compound-specific amino acid trophic position measurements: preparative high pressure liquid chromatography technique for purifying underivatized amino acids for stable isotope analysis. Limnology and Oceanography Methods, 12, 2014, 840-852. https://doi.org/10.4319/lom.2014.12.840
  • Cite as: McCarthy, Matthew D. (2024). N isotopic composition of Phenylalanine and Glutamic Acid from a number of organisms, demonstrating new HPLC protocol for precise isotopic measurements on 2017-08-02 (NCEI Accession 0292208). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://www.ncei.noaa.gov/archive/accession/0292208. Accessed [date].
gov.noaa.nodc:0292208
Download Data
  • HTTPS (download)
    Navigate directly to the URL for data access and direct download.
  • FTP (download)
    These data are available through the File Transfer Protocol (FTP). FTP is no longer supported by most internet browsers. You may copy and paste the FTP link to the data into an FTP client (e.g., FileZilla or WinSCP).
Distribution Formats
  • TSV
Ordering Instructions Contact NCEI for other distribution options and instructions.
Distributor NOAA National Centers for Environmental Information
+1-301-713-3277
NCEI.Info@noaa.gov
Dataset Point of Contact NOAA National Centers for Environmental Information
ncei.info@noaa.gov
Coverage Description California Margin , Santa Barbara Basin , CA current system, Eastern Tropical Pacific
Time Period 2017-08-02 to 2017-08-02
Spatial Bounding Box Coordinates
West:
East:
South:
North:
Spatial Coverage Map
General Documentation
Associated Resources
  • Biological, chemical, physical, biogeochemical, ecological, environmental and other data collected from around the world during historical and contemporary periods of biological and chemical oceanographic exploration and research managed and submitted by the Biological and Chemical Oceanography Data Management Office (BCO-DMO)
    • NCEI Collection
      Navigate directly to the URL for data access and direct download.
  • McCarthy, M. D. (2017) N isotopic composition of Phenylalanine and Glutamic Acid from a number of organisms, demonstrating new HPLC protocol for precise isotopic measurements. Biological and Chemical Oceanography Data Management Office (BCO-DMO). Dataset version 2017-08-02. https://doi.org/10.1575/1912/bco-dmo.712090.1
  • Parent ID (indicates this dataset is related to other data):
    • gov.noaa.nodc:BCO-DMO
Publication Dates
  • publication: 2024-05-02
Data Presentation Form Digital table - digital representation of facts or figures systematically displayed, especially in columns
Dataset Progress Status Complete - production of the data has been completed
Historical archive - data has been stored in an offline storage facility
Data Update Frequency As needed
Supplemental Information
Acquisition Description:
Methodology described in Broek & McCarthy (2014):

AA standards
Standard L-AA powders were purchased from Alfa Aesar and Acros Organics and used to prepare individual liquid standards (0.05 M), which were then combined as an equimolar mixture of 16 individual AAs ("16 AA Standard") for developing separations. The 16 AA Standard contained the proteinaceous AAs: glycine (Gly), L-alanine (Ala), L-arginine (Arg), L-aspartic acid (Asp), L-glutamic acid (Glu), L-histidine His), L-isoleucine (Ile), L-leucine (Leu), L-lysine (Lys), D/L-methionine (Met), L-phenylalanine (Phe), L-proline (Pro), L-serine (Ser), L-threonine (Thr), L-valine (Val); and nonprotein AA nor-leucine(Nle), which ;is commonly used as an internal standard (Popp et al. 2007; McCarthy et al. 2013). The δ15N and δ13C values for dry standards were determined by standard EA-IRMS at the University of California, Santa Cruz Stable Isotope Laboratory (UCSC-SIL) following standard protocols (http://es.ucsc.edu/ ~ silab). Average precision of EA-IRMS δ15N standard values was 0.11 ± 0.07 ‰. Additionally, a commercially available equimolar AA standard mixture "Pierce Amino Acid Standard H" (Pierce H)(Thermo Scientific) containing the same AAs as the "16 AA Standard" with the exception of the nonprotein AA Nle and addition of the proteinaceous AAscysteine (Cys) and tyrosine (Tyr) was used to construct individual calibration curves, so as to verify relative molar abundance of individual AAs in natural samples.

Sample preparation:
The cyanobacteria sample ( Spirulina Sp.) was obtained as a bulk commercial dry powder (Spirulina Pacifica, Nutrex Hawaii, Kailua-Kona, HI). This same sample has been used previously as a McCarthy laboratory internal quality control standard, and its CSI-AA values have been measured repeatedly by GC-C-IRMS, allowing an investigation of the long-term accuracy and precision of the GC-C-IRMS instrument.

Coastal mussel ( Myilitus Califorianus) sample was collected in 2012 from Santa Cruz, CA. The mussel was previously dissected, and the adductor muscle tissue removed and lyophilized prior to storage. We used a subsample of adductor muscle collected for a prior study (Vokhshoori and McCarthy 2014) hydrolyzing the bulk lyophilized adductor muscle tissue directly without lipid extraction.

The deep-sea bamboo coral (genus isidella ) sample was previously collected in 2007 from Monterey Bay, CA, USA (36 44.6538N, 122 2.2329W, 870.2 m) (Hill, pers. comm. 2011). A proteinaceous node was separated from the calcium carbonate skeleton and oven dried (60 degrees C, 24 h).

White sea bass muscle tissue was subsampled from an incidental recreational catch in 2007, landed from Santa Cruz Island, Channel Islands, CA (J. Patterson, pers. comm. 2007). Fish muscle tissue was also lyophilized prior to hydrolysis.

Harbor seal blood was collected in May-June 2007 from a wild animal in Tomales Bay, CA (38 13.9N, 122 58.1W) under NMFS Research Permit no. 555-1565. Blood serum was purified, lipid extracted, and lyophilized prior to hydrolysis, as described previously (Germain et al. 2011).

For all sample types, proteinaceous material was hydrolyzed by adding 40-50 mg of bulk dry sample to an 8 mL glass vial, followed by 5 mL of 6 N hydrochloric acid (HCl) at room temperature. The vials were flushed with nitrogen gas, sealed, and allowed to hydrolyze under standard conditions (110 degrees C, 20 h). Hydrolysis under acidic conditions quantitatively deaminates asparagine (Asn) to aspartic acid, and glutamine (Gln) to glutamic acid (Barrett 1985). Therefore, in this protocol (and all others based on acid hydrolysis), measured Glu in fact represents Gln+Glu, and measured Asp represents Asp+Asn. We note that while the abbreviations Glx and Asx are sometimes used to denote these combined Gln+Glu and Asp+Asn fractions, we have elected to simply use Asp and Glu as abbreviations, as defined above, in order to correspond better with prior TP CSIA literature. Additionally, acid hydrolysis is known to destroy cysteine (Cys), precluding it from analysis (Barrett 1985). Resulting hydrolysates were dried to completion under nitrogen gas and brought up in 0.1 N HCl to a final concentration of 1 mg tissue/ 100 L HCl. Approximately 75% of each of the resulting mixtures was reserved for HPLC/EA-IRMS analysis, and the remaining material was dried to completion for derivatization and subsequent GC-C-IRMS analysis.

GC-C-IRMS Analysis :
Trifluoroacetyl isopropyl ester (TFA-IP) AA derivatives were prepared using standardized lab protocols, as described previously (McCarthy et al. 2013). Briefly, hydrolyzed samples were esterified in 300 uL 1:5 mixture of acetyl chloride:2-propanol (110 degrees C, 60 minutes). The resulting amino acid isopropyl esters were then acylated in 350 uL 1:3 mixture of dichloromethane (DCM):trifluoroacetic acid anhydride (100 degrees C, 15 minutes). Derivatized AAs were dissolved in DCM to a final ratio of 1 mg of original proteinaceous material to 50 uL DCM. Isotopic analysis was conducted on a Thermo Trace GC Ultra (Thermo Fisher Scientific, West Palm Beach, FL, USA) coupled via a Thermo GC IsoLink to a ThermoFinnigan DeltaPlus XP isotope ratio monitoring mass spectrometer (Thermo Fisher Scientific). Derivatives (1 L) were injected (injector temp. 250 degrees C constant) onto an Agilent DB-5 column (50 m x 0.32 mm ID x 0.52 um film thickness, Agilent Technologies, Inc., Santa Clara, CA, USA), with a He carrier flow rate of 2 mL/min (constant-flow). Separations were achieved with a four-ramp oven program: 52 deg C, 2 min hold; ramp 1 = 15 deg C /min to 75 deg C, hold for 2 min; ramp 2 = 4 deg C /min to 185 deg C, hold for 2 min; ramp 3 = 4 deg C /min to 200 deg C; ramp 4 = 30 deg C /min to 240 deg C, hold for 5 min. This method allows for the determination of 11-15 AAs depending on derivatization efficiency and instrument sensitivity. Values are typically obtained for Gly, Ala, Glu, Ile, Leu, Phe, Pro, Ser, Thr, Val, Nle, and Lys. Values for Met, His and Arg are obtained only in some samples, depending on concentration and derivatization efficiency. For δ 15 N AA values, samples were analyzed in quadruplicate (n=4) with bracketed lab AA isotopic standard mix for subsequent standard offset and drift corrections. Corrections based on authentic external standards were applied using previously published protocols (McCarthy et al. 2013).

HPLC/EA-IRMS:
Liquid chromatographic separations were conducted using a Shimadzu HPLC system (Shimadzu Scientific Instruments, Inc., Columbia, MD, USA) equipped with: system controller (SCL-10A vp), degasser (DGU-20A5), 2 pumps (LC-20AD), autosampler (SIL-20A) with an adjustable injection volume of 0.1-100 uL, and coupled to a Shimadzu automated fraction collector (FRC-20A). An adjustable flow splitter (Analytical Sales and Services, Inc., Pompton Plains, NJ, USA) was used inline following the chromatography column to direct ~15% of the flow to a SEDERE (Alfortville, France) evaporative light scattering detector (ELSD-LT II, Sedex 85LT) for peak detection and quantitation. A semi-preparative scale SiELC Primesep A column (10 x 250 mm, 100 angstrom pore size, 5 um particle size; SiELC Technologies Ltd., Prospect Heights, IL, USA) was used for amino acid purification. The Primesep A column used here is a reverse-phase semi-preparative scale column embedded with strong acidic ion-pairing groups. Such mixed phase columns have been developed specifically for the separation of charged organic compounds as the acidic sites in the stationary phase interact with the charged functional groups and provide additional retention mechanisms to increase chromatographic separation potential. For a more detailed description of the retention mechanisms of the Primesep A column see (McCullagh et al. 2006; 2010).

Typically, 75-100 uL of sample solution was loaded onto the HPLC instrument. A binary solvent ramp program was used consisting of 0.1% trifluoroacetic acid (TFA) in HPLC grade water (aqueous phase) and 0.1% TFA in acetonitrile (organic phase). The final solvent ramp program used for optimal separation was as follows: starting with 100% aqueous / 0% organic; increased from 0 to 0.5% organic from 0-30 minutes; increased to 15% organic from 30-35 minutes; increased to 22.5% from 35-70 minutes; increased to 30% from 70-95 minutes; held at 30% until 140 minutes. The column was then cleaned and equilibrated by increasing to 100% and holding for 20 minutes; then decreasing to 50% and holding for an additional 15 minutes; then decreasing to 0% and holding until the method ends at 180 minutes. A flow rate ramp is also employed in which the total flow rate is held at 2.5 mL/minute for 0-30 minutes; increased to 4.5 mL/minute from 30-35 minutes; held at 4.5 mL/min from 35-170 minutes; then decreased back to 2.5 mL/minute from 170-175 minutes and held until the completion of the analysis.

Purified AAs were collected into 3.5 mL tubes via the automated fraction collector using time-based collections, and then transferred to 20 mL glass vials. The solvent was removed under vacuum using a Jouan centrifugal evaporator (Societe Jouan, Saint-Herblain, France) at a chamber temperature of 60 degrees C. Dry AA residues were then re-dissolved into a small volume (~30 L) of 0.1 N HCl, transferred into pre-ashed tin (Sn) EA capsules, and dried to completion in a 60 degrees C oven for 12 hours. Capsules were then pressed into cubes and analyzed for δ 15 N and δ 13 C values by EA-IRMS. EA-IRMS analysis was conducted in the UCSC shared Stable Isotope Laboratory facility (UCSC-SIL), using an EA-IRMS analyzer dedicated to smaller samples. This system uses a Carlo Erba CHNS-O EA1108-Elemental Analyzer, interfaced via a Thermo Finnigan Gasbench II device to a Thermo Finnigan Delta Plus XP isotope ratio mass spectrometer (Thermo Fisher Scientific), configured after Polissar et al. (2009). For AAs in this study, we found that ≤ 100 nmol quantities of purified AA material could be routinely measured using this instrument, although as discussed below a standard EA configuration could also equally be used. Raw EA-IRMS δ 15 N and δ 13 C values were corrected for instrument drift and size effects using AA isotopic standards and standard correction protocols used by the UCSC-SIL ( http://es.ucsc.edu/~silab ).
Purpose This dataset is available to the public for a wide variety of uses including scientific research and analysis.
Use Limitations
  • accessLevel: Public
  • Distribution liability: NOAA and NCEI make no warranty, expressed or implied, regarding these data, nor does the fact of distribution constitute such a warranty. NOAA and NCEI cannot assume liability for any damages caused by any errors or omissions in these data. If appropriate, NCEI can only certify that the data it distributes are an authentic copy of the records that were accepted for inclusion in the NCEI archives.
Dataset Citation
  • Cite as: McCarthy, Matthew D. (2024). N isotopic composition of Phenylalanine and Glutamic Acid from a number of organisms, demonstrating new HPLC protocol for precise isotopic measurements on 2017-08-02 (NCEI Accession 0292208). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://www.ncei.noaa.gov/archive/accession/0292208. Accessed [date].
Cited Authors
Principal Investigators
Contributors
Resource Providers
Points of Contact
Publishers
Acknowledgments
Theme keywords NODC DATA TYPES THESAURUS NODC OBSERVATION TYPES THESAURUS WMO_CategoryCode
  • oceanography
BCO-DMO Standard Parameters Global Change Master Directory (GCMD) Science Keywords Originator Parameter Names
Data Center keywords NODC COLLECTING INSTITUTION NAMES THESAURUS NODC SUBMITTING INSTITUTION NAMES THESAURUS Global Change Master Directory (GCMD) Data Center Keywords
Instrument keywords NODC INSTRUMENT TYPES THESAURUS BCO-DMO Standard Instruments Global Change Master Directory (GCMD) Instrument Keywords Originator Instrument Names
Project keywords BCO-DMO Standard Projects Provider Funding Award Information
Keywords NCEI ACCESSION NUMBER
Use Constraints
  • Cite as: McCarthy, Matthew D. (2024). N isotopic composition of Phenylalanine and Glutamic Acid from a number of organisms, demonstrating new HPLC protocol for precise isotopic measurements on 2017-08-02 (NCEI Accession 0292208). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://www.ncei.noaa.gov/archive/accession/0292208. Accessed [date].
Data License
Access Constraints
  • Use liability: NOAA and NCEI cannot provide any warranty as to the accuracy, reliability, or completeness of furnished data. Users assume responsibility to determine the usability of these data. The user is responsible for the results of any application of this data for other than its intended purpose.
Fees
  • In most cases, electronic downloads of the data are free. However, fees may apply for custom orders, data certifications, copies of analog materials, and data distribution on physical media.
Lineage information for: dataset
Processing Steps
  • 2024-05-02T17:37:52Z - NCEI Accession 0292208 v1.1 was published.
Output Datasets
Acquisition Information (collection)
Instrument
  • chromatograph
  • mass spectrometer
Last Modified: 2024-05-31T15:15:28Z
For questions about the information on this page, please email: ncei.info@noaa.gov