Skip to main content
Dataset Overview | National Centers for Environmental Information (NCEI)

Dissolved macronutrient concentrations from incubation experiments performed on RVIB Nathaniel B. Palmer cruise NBP 16-08 from September to October 2016 (NCEI Accession 0278187)

browse graphicGraphic not available.
This dataset contains chemical data collected on RVIB Nathaniel B. Palmer during cruise NBP1608 from 2016-09-13 to 2016-10-09. These data include Ammonium, Nitrite, Silicate, nitrate plus nitrite, and reactive phosphorus (PO4). The instruments used to collect these data include Flow Injection Analyzer and Technicon AutoAnalyzerII. These data were collected by Phoebe Dreux Chappell of Old Dominion University, Bethany D. Jenkins of University of Rhode Island, and Kristen N. Buck of University of South Florida as part of the "Collaborative Research: Investigating Iron-binding Ligands in Southern Ocean Diatom Communities: The Role of Diatom-Bacteria Associations (Diatom_Bacteria_Ligands)" project. The Biological and Chemical Oceanography Data Management Office (BCO-DMO) submitted these data to NCEI on 2020-01-03.

The following is the text of the dataset description provided by BCO-DMO:

NBP16-08 incubation dissolved macronutrient concentrations

Dataset Description:
NBP16-08 incubation dissolved macronutrient concentrations.
  • Cite as: Buck, Kristen; Chappell, Phoebe Dreux; Jenkins, Bethany D. (2023). Dissolved macronutrient concentrations from incubation experiments performed on RVIB Nathaniel B. Palmer cruise NBP 16-08 from September to October 2016 (NCEI Accession 0278187). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://www.ncei.noaa.gov/archive/accession/0278187. Accessed [date].
gov.noaa.nodc:0278187
Download Data
  • HTTPS (download)
    Navigate directly to the URL for data access and direct download.
  • FTP (download)
    These data are available through the File Transfer Protocol (FTP). FTP is no longer supported by most internet browsers. You may copy and paste the FTP link to the data into an FTP client (e.g., FileZilla or WinSCP).
Distribution Formats
  • TSV
Ordering Instructions Contact NCEI for other distribution options and instructions.
Distributor NOAA National Centers for Environmental Information
+1-301-713-3277
NCEI.Info@noaa.gov
Dataset Point of Contact NOAA National Centers for Environmental Information
ncei.info@noaa.gov
Time Period 2016-09-13 to 2016-10-09
Spatial Bounding Box Coordinates
West: -64.647
East: -59.565
South: -62.46
North: -62.332
Spatial Coverage Map
General Documentation
Associated Resources
  • Biological, chemical, physical, biogeochemical, ecological, environmental and other data collected from around the world during historical and contemporary periods of biological and chemical oceanographic exploration and research managed and submitted by the Biological and Chemical Oceanography Data Management Office (BCO-DMO)
    • NCEI Collection
      Navigate directly to the URL for data access and direct download.
  • Buck, K. N., Jenkins, B. D., Chappell, P. D. (2018) Dissolved macronutrient concentrations from incubation experiments performed on RVIB Nathaniel B. Palmer cruise NBP 16-08 from September to October 2016. Biological and Chemical Oceanography Data Management Office (BCO-DMO). Dataset version 2018-07-31. https://doi.org/10.1575/1912/bco-dmo.743072.1
  • Parent ID (indicates this dataset is related to other data):
    • gov.noaa.nodc:BCO-DMO
Publication Dates
  • publication: 2023-05-14
Data Presentation Form Digital table - digital representation of facts or figures systematically displayed, especially in columns
Dataset Progress Status Complete - production of the data has been completed
Historical archive - data has been stored in an offline storage facility
Data Update Frequency As needed
Supplemental Information
Acquisition Description:
Sampling and analytical procedures:
Incubation 1 was setup from unfiltered seawater collected aboard the R/V/I/B Nathanial B. Palmer using a SeaBird GEOTRACES style SBE32 rosette system deployed on a conducting Kevlar line with OceanTestEquipment, Inc. X-Niskin samplers modified for trace element sampling. Seawater was collected from three consecutive casts to 25-35 m depth at -62.332N, -64.647E and the seawater from each cast was homogenized in three acid-cleaned and Milli-Q (>18.2 MΩ cm) conditioned 50-L polypropylene carboys, then distributed into acid-cleaned and Milli-Q conditioned 4-L polycarbonate incubation bottles that were rinsed three times with the seawater prior to filling. Once filled, incubation bottles were spiked with their treatments in laminar flow hoods in a shipboard trace metal bubble, sealed with the caps wrapped in parafilm and placed in a 2 ºC temperature-controlled lit incubator van with 24 hour blue light (Hopkinson et al. 2007). Dark treatment bottles were placed in the same van but wrapped in heavy-duty black construction garbage bags.

Incubation 2 was setup from unfiltered seawater collected aboard the R/V/I/B Nathanial B. Palmer using a SeaBird GEOTRACES style SBE32 rosette system deployed on a conducting Kevlar line with OceanTestEquipment, Inc. X-Niskin samplers modified for trace element sampling. Seawater was collected from two consecutive casts to 25-35 m depth at -62.46N, -59.565E and the seawater from each cast was homogenized in three acid-cleaned and Milli-Q (>18.2 MΩ cm) conditioned 50-L polypropylene carboys, then distributed into acid-cleaned and Milli-Q conditioned 4-L polycarbonate incubation bottles that were rinsed three times with the seawater prior to filling. Once filled, incubation bottles were spiked with their treatments in laminar flow hoods in a shipboard trace metal bubble, sealed with the caps wrapped in parafilm and placed in a 2 ºC temperature-controlled lit incubator van with 24 hour blue light (Hopkinson et al. 2007). Dark treatment bottles were placed in the same van but wrapped in heavy-duty black construction garbage bags.

Incubation 3 was setup from a combination of filtered and unfiltered seawater collected aboard the R/V/I/B Nathanial B. Palmer using a SeaBird GEOTRACES style SBE32 rosette system deployed on a conducting Kevlar line with OceanTestEquipment, Inc. X-Niskin samplers modified for trace element sampling. Seawater was collected from one cast to 25-35 m depth at -62.46N, -59.565E, the location of Incubation 2, filtered through a 0.2 um Acropak membrane capsule filter (Pall) and stored in an acid-cleaned and Milli-Q (>18.2 MΩ cm) conditioned 50-L polypropylene carboy. Additional unfiltered seawater was collected from one cast to 25-35 m depth at -62.332N, -64.647E, the location of Incubation 1, and homogenized in two acid-cleaned and Milli-Q (>18.2 MΩ cm) conditioned 50-L polypropylene carboys. The unfiltered water from the Incubation 1 station was distributed into acid-cleaned and Milli-Q conditioned 4-L polycarbonate incubation bottles that were rinsed three times with the seawater prior to filling and used for one treatment of Incubation 3 (Q in the light, V in the dark). The filtered seawater from the Incubation 2 station was mixed in a 50:50 ratio with the unfiltered water from the Incubation 1 station in acid-cleaned and Milli-Q conditioned 4-L polycarbonate incubation bottles that were rinsed three times with the seawater prior to filling and used for the second treatment in Incubation 3 (R in the light, W in the dark). Once filled, incubation bottles were sealed with the caps wrapped in parafilm and placed in a 2 ºC temperature-controlled lit incubator van with 24 hour blue light (Hopkinson et al. 2007). Dark treatment bottles were placed in the same van but wrapped in heavy-duty black construction garbage bags.

For all incubations, samples for macronutrients were filtered through sequential 5 um and 0.4 um acid-cleaned polycarbonate track etched filters (Whatman Nuclepore) on Teflon filtration rigs (Savillex) and the filtrate collected in 50 mL Falcon tubes that had been rinsed with distilled water (DIW), soaked overnight in 10% hydrocholoric acid (HCl, Fisher, Trace Metal Grade), rinsed three times with DIW again, dried and rinsed three times with sample prior to filling. Samples were analyzed shipboard, typically within 24 hours, for nitrate+nitrite, phosphate, silicate, and occasionally nitrite. Until analyzed shipboard, samples were stored sealed at 4 ºC in the dark and, following analyses, samples were frozen at -20 ºC and shipped back to the University of South Florida for laboratory-based analyses of nitrite and ammonium, and in some cases again for nitrate+nitrite, phosphate and silicate.

Analytical methodology was based on established methods (Parsons 1984; Gordon et al. 1993) as described for the Lachat 8500 QuickChem in the Lachat QuickChem methods manuals and for the Technicon AAII in the CARIACO methods manual. All labware were either glass or high density polyethylene and were cleaned by an initial distilled water (DIW) rinse, followed by an overnight 10% hydrochloric acid (Fisher, Trace Metal Grade) soak, then rinsed three times with DIW and three times with solvent, analyte or sample prior to fill. Dedicated glassware was used for reagents and standards to avoid cross contamination issues. All reagents were made in high purity Milli-Q (>18 MΩ cm) water.

An artificial seawater matrix was used as the carrier for the analyses on the Lachat QuickChem 8500 at sea and on the Technicon AAII in the lab. 4L batches of artificial seawater were made by dissolving pre-weighed salts (128.50 g NaCl, 28.50 g MgSO4*7H2O, 0.6714 g NaHCO3) in Milli-Q to match Southern Ocean seawater salinity and adjusted to match Southern Ocean seawater pH with 10% hydrochloric acid.

Five-point standard curves were analyzed in duplicate at the beginning and end of each run with duplicate reagent blanks, and quality control checks every seventh sample. Quality control check consisted of either an international reference sample or a quality control sample. The certified nutrient reference samples used, lots CC and CD, were purchased from Kanso Technos in Osaka, Japan. The quality control sample was made from a 20-L homogenized surface Southern Ocean filtered and autoclaved seawater sample. The midpoint standard from the calibration curve was also analyzed every fourteenth sample to check for drift during the runs.

Detection limits for all five parameters on the two instruments used were determined from three times the standard deviation of replicate artificial seawater blanks (n>6). On the Lachat QuickChem 8500, limits of detection were 0.01 uM for nitrate+nitrite, 0.02 uM for phosphate, 0.03 uM for silicate, 0.05 uM for nitrite and 0.5 uM for ammonium. On the Technicon AAII, limits of detection were 0.06 uM for nitrate+nitrite, 0.02 uM for phosphate, 0.2 uM for silicate, 0.01 uM for nitrite, and 0.05 uM for ammonium.

Sample analyses for macronutrients were performed by William Abbott (USF).

Gordon, L.I., Jennings, J., J.C., Ross, A.A. and Krest, J.M. 1993. A suggested protocol for continuous flow automated analysis of seawater nutrients (phosphate, nitrate, nitrite and silicic acid) in the WOCE Hydrographic Program and the Joint Global Ocean Fluxes Study, Methods Manual WHPO 91-1. WOCE Hydrographic Program Office.

Hopkinson, B. M., B. G. Mitchell, R. A. Reynolds, H. Wang, K. E. Selph, C. I. Measures, C. D. Hewes, O. Holm-Hansen, and K. A. Barbeau. 2007. Iron limitation across chlorophyll gradients in the southern Drake Passage: Phytoplankton responses to iron addition and photosynthetic indicators of iron stress. Limnology and Oceanography 52: 2540-2554.

Parsons, T.R., Maita, Y. and Lalli, C.M. 1984. A manual of chemical and biological methods for seawater analysis. Pergammon Press, Oxford, 173 pp.
Purpose This dataset is available to the public for a wide variety of uses including scientific research and analysis.
Use Limitations
  • accessLevel: Public
  • Distribution liability: NOAA and NCEI make no warranty, expressed or implied, regarding these data, nor does the fact of distribution constitute such a warranty. NOAA and NCEI cannot assume liability for any damages caused by any errors or omissions in these data. If appropriate, NCEI can only certify that the data it distributes are an authentic copy of the records that were accepted for inclusion in the NCEI archives.
Dataset Citation
  • Cite as: Buck, Kristen; Chappell, Phoebe Dreux; Jenkins, Bethany D. (2023). Dissolved macronutrient concentrations from incubation experiments performed on RVIB Nathaniel B. Palmer cruise NBP 16-08 from September to October 2016 (NCEI Accession 0278187). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://www.ncei.noaa.gov/archive/accession/0278187. Accessed [date].
Cited Authors
Principal Investigators
Contributors
Resource Providers
Points of Contact
Publishers
Acknowledgments
Theme keywords NODC DATA TYPES THESAURUS NODC OBSERVATION TYPES THESAURUS WMO_CategoryCode
  • oceanography
BCO-DMO Standard Parameters Global Change Master Directory (GCMD) Science Keywords Originator Parameter Names
Data Center keywords NODC COLLECTING INSTITUTION NAMES THESAURUS NODC SUBMITTING INSTITUTION NAMES THESAURUS Global Change Master Directory (GCMD) Data Center Keywords
Platform keywords NODC PLATFORM NAMES THESAURUS BCO-DMO Platform Names Global Change Master Directory (GCMD) Platform Keywords ICES/SeaDataNet Ship Codes
Instrument keywords NODC INSTRUMENT TYPES THESAURUS BCO-DMO Standard Instruments Global Change Master Directory (GCMD) Instrument Keywords Originator Instrument Names
Place keywords Provider Place Names
Project keywords BCO-DMO Standard Projects Provider Cruise IDs Provider Funding Award Information
Keywords NCEI ACCESSION NUMBER
Use Constraints
  • Cite as: Buck, Kristen; Chappell, Phoebe Dreux; Jenkins, Bethany D. (2023). Dissolved macronutrient concentrations from incubation experiments performed on RVIB Nathaniel B. Palmer cruise NBP 16-08 from September to October 2016 (NCEI Accession 0278187). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://www.ncei.noaa.gov/archive/accession/0278187. Accessed [date].
Data License
Access Constraints
  • Use liability: NOAA and NCEI cannot provide any warranty as to the accuracy, reliability, or completeness of furnished data. Users assume responsibility to determine the usability of these data. The user is responsible for the results of any application of this data for other than its intended purpose.
Fees
  • In most cases, electronic downloads of the data are free. However, fees may apply for custom orders, data certifications, copies of analog materials, and data distribution on physical media.
Lineage information for: dataset
Processing Steps
  • 2023-05-14T04:37:36Z - NCEI Accession 0278187 v1.1 was published.
Output Datasets
Acquisition Information (collection)
Instrument
  • flow injection analyzer
Platform
  • RV Nathaniel B. Palmer
Last Modified: 2024-05-31T18:50:46Z
For questions about the information on this page, please email: ncei.info@noaa.gov