Skip to main content
Dataset Overview | National Centers for Environmental Information (NCEI)

Hydrocarbon concentrations, DIC isotopes, nutrients, and cyanobacteria counts from samples collected on R/V Neil Armstrong cruise AR16 in the western north Atlantic during May 2017 (NCEI Accession 0278069)

browse graphicPreview graphic
This dataset contains biological, chemical, optical, and physical data collected on R/V Neil Armstrong during cruise AR16 in the North Atlantic Ocean from 2017-05-04 to 2017-05-20. These data include Ammonium, Nitrate, Nitrite, PAR, Silicon, density, depth, fluorescence, and water temperature. The instruments used to collect these data include CTD Sea-Bird SBE 911plus, Flame Ionization Detector, Flow Cytometer, Gas Chromatograph, Isotope-ratio Mass Spectrometer, Niskin bottle, and Thermo Scientific GasBench II. These data were collected by Robert Swarthout of Appalachian State University, David L. Valentine of University of California-Santa Barbara, and Christopher Reddy of Woods Hole Oceanographic Institution as part of the "Collaborative Research: Do Cyanobacteria Drive Marine Hydrocarbon Biogeochemistry? (Cyanobacteria Hydrocarbons)" project. The Biological and Chemical Oceanography Data Management Office (BCO-DMO) submitted these data to NCEI on 2020-12-03.

The following is the text of the dataset description provided by BCO-DMO:

Acquisition Description:
in situ Sampling and Quantification of Hydrocarbon Production
Water was collected with a rosette equipped with 12 L Niskin bottles just after sunrise (~ 8 AM) for all sampling except for the diel experiment. Salinity, density, temperature, fluorescence and percent photosynthetically active radiation (% PAR) were measured semi-continuously for each hydrocast. For diel sampling, a Lagrangian framework was used by following deployed particle traps set just below the DCM (150 m) and sampled at six-hour intervals through a full 24-hour cycle. Sampling targeted six light-penetration levels with depths held constant following initial collection, plus the DCM, which is a depth-variable feature. Water was collected from the Niskin into 2 L polycarbonate bottles via a polyvinyl chloride tube equipped with a 200 m mesh to filter out large zooplankton.

For in situ hydrocarbon concentration measurements, water in the 2 L polycarbonate bottles was immediately filtered through a 0.22 m Teflon filter under gentle vacuum with an oil-less vacuum pump. For the hydrocarbon production experiment ¹³C-bicarbonate tracer solution (with 45 g/L NaCl to sink the tracer to the bottom of the bottle) made from ¹³C-sodium bicarbonate (Cambridge Isotope Laboratories Inc., ¹³C 99%) was added to the 2L polycarbonate bottles to achieve a 480 ‰ enrichment in seawater DIC. Dark control bottles were covered completely beforehand with aluminum foil before tracer addition and kill control bottles were treated with Zinc Chloride to 2% ZnCl₂ (m/v) before tracer addition. 2 L bottles were then immediately placed into black mesh bags to attenuate light to the value from which it was collected (either 30%, 10% or 1% PAR) and placed into on-board seawater incubators with a continuous flow of surface water; this was marked as the start of incubation. Bottles were harvested at 0 hour (initial), 5, 10, 20 and 30 hour (final) time points for the 30% PAR light bags and at t = 0 hour and t = 30 hour final for the 10% and 1% light levels, care was taken to reduce light exposure in the ship-board laboratory when preparing for incubation by placing bottles into covered tubs. A 2 mL aliquot was taken for ¹³C-DIC prior to filtration. Filters were placed into pre-combusted aluminum foil packets and immediately frozen at -20 C for later analysis.

Hydrocarbon Extraction and Analysis
A modified Bligh-Dyer method was used to extract hydrocarbons from membranes of frozen cells collected on Teflon filters. Dodecahydrotriphenylene (internal standard) and C23 ethyl ester (chromatographically remote secondary internal standard) were added to the dry filter before extraction. Once extracted into dichloromethane, sodium sulfate was added for drying, ~40 L of toluene was added to prevent complete dryness of the extracts and then the solution was rotary evaporated to ~30 L and placed into a 2 mL GC-vial with a combusted glass insert. Before analysis, a small volume of C23 methyl ester (external standard) was added. All glassware and solid chemicals were pre-combusted before use. Concentration analysis was done on a gas chromatograph flame ionization detector (GC-FID). GC-FID was performed with a 30 m x 0.25 mm ID, 0.25 m pore size, fused silica Restek 13323 Rxi-1 MS Capillary Column with a splitless 2 L injection. Initial oven temperature was at 70 °C held for 2 minutes, a 3 °C min⁻¹ ramp to 120 °C, then a 6 °C min⁻¹ ramp to the final temperature of 320 °C. A standard mix of pentadecane, heptadecane, internal standard, external standard and transesterification standard was run to calibrate response factors for every batch of samples (~20 per batch). Blanks were run every ~ six samples and peaks were manually integrated, there were no co-eluting peaks for pentadecane or heptadecane. Comprehensive two-dimensional chromatography was used on select samples to check for other hydrocarbons, contaminants, and quality of blank filters run through the extractive process.

Compound-specific and Dissolved Inorganic Carbon Isotope Measurements
Compound-specific isotope analysis was performed after concentration analysis on a gas chromatograph combustion isotope ratio mass spectrometer (GC/C-IRMS) with a Trace GC (Thermo Finnigan) set up to a GC-C/TC III (FinniganTM) interface and a Deltaplus XP isotope ratio mass spectrometer (Thermo Finnigan). A J & W Scientific DB-5 Capillary column (30 m, 0.25 mm, 0.25 m) was used with 2 L manual injections. Temperature ramp was conducted starting at 70 °C and held for 2 minutes, then a 3 °C min-1 ramp to 120 °C, hold for 0 minutes, then a 6 °C min-1 ramp to 185 °C, hold for 0 minutes then a 120 °C min⁻¹ ramp to 290 °C, hold for 3 minutes. Inlet temperature was 260 °C, flow rate was held at 2.2 mL He min-1 with a splitless injection held for 0.5 minutes after injection. Isotope ratio accuracy was calibrated with a C14 fatty acid methyl ester Schimmelmann reference material to Vienna PeeDee Belemnite. Precision was accounted for with a standard mix of nC15, nC16 and nC17 at ~1.2 ng L-1 and was run between every batch of ~20 samples. Peaks were manually integrated after establishing the baseline, analytical precision was ~0.9 ‰ δ13C for pentadecane. Dissolved inorganic carbon 13C isotope ratio measurements were made on a Gas Bench II (Thermo Finnigan) interfaced to the same Deltaplus XP isotope ratio mass spectrometer (Thermo Finnigan) used for the compound-specific analysis. Sample preparation and analysis were followed closely to the protocol outlines by the University of California, Davis, Stable Isotope Facility ( https://stableisotopefacility.ucdavis.edu/dictracegas.html ).

Cell Counts and Dissolved Nutrient Analysis
Sampling for nutrients and cell counts was conducted on the CTD cast immediately before the casts for hydrocarbon sampling (~ 1-hour difference), these casts were all at ~sunrise. Parallel sampling was conducted with the same cast water for the diel sampling. Flow cytometry analysis was performed by the Bigelow Laboratory for Ocean Sciences using a slightly modified protocol from Lomas et al., 2010. Samples were fixed with paraformaldehyde (0.5% final concentration) and stored at ~4 °C for 1-2 hours before long term storage in liquid nitrogen. An Influx cytometer was used with a 488 nm blue excitation laser, appropriate Chl-a (692 ± 20 nm) and phycoerythrin (585 ± 15 nm) bandpass filters, and was calibrated daily with 3.46 µm Rainbow Beads (Spherotech Inc. Lake Forest, Illinois, USA). Each sample was run for 4–6 min (∼0.2–0.3 ml total volume analyzed), with log-amplified Chl-a and phycoerythrin fluorescence, and forward and right-angle scatter signals recorded. Data files were analyzed from two-dimensional scatter plots based on red or orange fluorescence and characteristic light scattering properties using FlowJo 9.8 Software (Becton Dickinson, San Jose, CA). Pico-autotrophs were identified as either Synechococcus or Prochlorococcus , pico-eukaryotes based upon cell size and the presence or absence of phycoerythrin, respectively. Nutrients were analyzed by the University of Washington Marine Chemistry Laboratory.
  • Cite as: Valentine, David L.; Reddy, Christopher; Swarthout, Robert (2023). Hydrocarbon concentrations, DIC isotopes, nutrients, and cyanobacteria counts from samples collected on R/V Neil Armstrong cruise AR16 in the western north Atlantic during May 2017 (NCEI Accession 0278069). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://www.ncei.noaa.gov/archive/accession/0278069. Accessed [date].
gov.noaa.nodc:0278069
Download Data
  • HTTPS (download)
    Navigate directly to the URL for data access and direct download.
  • FTP (download)
    These data are available through the File Transfer Protocol (FTP). FTP is no longer supported by most internet browsers. You may copy and paste the FTP link to the data into an FTP client (e.g., FileZilla or WinSCP).
Distribution Formats
  • TSV
Ordering Instructions Contact NCEI for other distribution options and instructions.
Distributor NOAA National Centers for Environmental Information
+1-301-713-3277
NCEI.Info@noaa.gov
Dataset Point of Contact NOAA National Centers for Environmental Information
ncei.info@noaa.gov
Time Period 2017-05-04 to 2017-05-20
Spatial Bounding Box Coordinates
West: -71.399
East: -64.164
South: 29.047
North: 40.421
Spatial Coverage Map
General Documentation
Associated Resources
  • Biological, chemical, physical, biogeochemical, ecological, environmental and other data collected from around the world during historical and contemporary periods of biological and chemical oceanographic exploration and research managed and submitted by the Biological and Chemical Oceanography Data Management Office (BCO-DMO)
    • NCEI Collection
      Navigate directly to the URL for data access and direct download.
  • Valentine, D. L., Swarthout, R., Reddy, C. (2020) Hydrocarbon concentrations, DIC isotopes, nutrients, and cyanobacteria counts from samples collected on R/V Neil Armstrong cruise AR16 in the western north Atlantic during May 2017. Biological and Chemical Oceanography Data Management Office (BCO-DMO). (Version 1) Version Date 2020-10-16. https://doi.org/10.26008/1912/bco-dmo.826878.1
  • Parent ID (indicates this dataset is related to other data):
    • gov.noaa.nodc:BCO-DMO
Publication Dates
  • publication: 2023-05-12
Data Presentation Form Digital table - digital representation of facts or figures systematically displayed, especially in columns
Dataset Progress Status Complete - production of the data has been completed
Historical archive - data has been stored in an offline storage facility
Data Update Frequency As needed
Purpose This dataset is available to the public for a wide variety of uses including scientific research and analysis.
Use Limitations
  • accessLevel: Public
  • Distribution liability: NOAA and NCEI make no warranty, expressed or implied, regarding these data, nor does the fact of distribution constitute such a warranty. NOAA and NCEI cannot assume liability for any damages caused by any errors or omissions in these data. If appropriate, NCEI can only certify that the data it distributes are an authentic copy of the records that were accepted for inclusion in the NCEI archives.
Dataset Citation
  • Cite as: Valentine, David L.; Reddy, Christopher; Swarthout, Robert (2023). Hydrocarbon concentrations, DIC isotopes, nutrients, and cyanobacteria counts from samples collected on R/V Neil Armstrong cruise AR16 in the western north Atlantic during May 2017 (NCEI Accession 0278069). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://www.ncei.noaa.gov/archive/accession/0278069. Accessed [date].
Cited Authors
Principal Investigators
Contributors
Resource Providers
Points of Contact
Publishers
Acknowledgments
Theme keywords NODC DATA TYPES THESAURUS NODC OBSERVATION TYPES THESAURUS WMO_CategoryCode
  • oceanography
BCO-DMO Standard Parameters Global Change Master Directory (GCMD) Science Keywords Originator Parameter Names
Data Center keywords NODC COLLECTING INSTITUTION NAMES THESAURUS NODC SUBMITTING INSTITUTION NAMES THESAURUS Global Change Master Directory (GCMD) Data Center Keywords
Platform keywords NODC PLATFORM NAMES THESAURUS BCO-DMO Platform Names Global Change Master Directory (GCMD) Platform Keywords ICES/SeaDataNet Ship Codes
Instrument keywords NODC INSTRUMENT TYPES THESAURUS BCO-DMO Standard Instruments Global Change Master Directory (GCMD) Instrument Keywords Originator Instrument Names
Place keywords NODC SEA AREA NAMES THESAURUS Global Change Master Directory (GCMD) Location Keywords Provider Place Names
Project keywords BCO-DMO Standard Projects Provider Cruise IDs Provider Funding Award Information
Keywords NCEI ACCESSION NUMBER
Use Constraints
  • Cite as: Valentine, David L.; Reddy, Christopher; Swarthout, Robert (2023). Hydrocarbon concentrations, DIC isotopes, nutrients, and cyanobacteria counts from samples collected on R/V Neil Armstrong cruise AR16 in the western north Atlantic during May 2017 (NCEI Accession 0278069). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://www.ncei.noaa.gov/archive/accession/0278069. Accessed [date].
Data License
Access Constraints
  • Use liability: NOAA and NCEI cannot provide any warranty as to the accuracy, reliability, or completeness of furnished data. Users assume responsibility to determine the usability of these data. The user is responsible for the results of any application of this data for other than its intended purpose.
Fees
  • In most cases, electronic downloads of the data are free. However, fees may apply for custom orders, data certifications, copies of analog materials, and data distribution on physical media.
Lineage information for: dataset
Processing Steps
  • 2023-05-12T04:02:30Z - NCEI Accession 0278069 v1.1 was published.
Output Datasets
Acquisition Information (collection)
Instrument
  • bottle
  • chromatograph
  • CTD
  • Flow Cytometer
  • mass spectrometer
Platform
  • RV Neil Armstrong
Last Modified: 2024-06-26T18:45:28Z
For questions about the information on this page, please email: ncei.info@noaa.gov