ODF bottle data along the US GEOTRACES East Pacific Zonal Transect from the R/V Thomas G. Thompson TN303 cruise in the tropical Pacific from Peru to Tahiti during 2013 (U.S. GEOTRACES EPZT project) (NCEI Accession 0277287)
This dataset contains chemical and physical data collected on R/V Thomas G. Thompson during cruise TN303 in the South Pacific Ocean from 2013-10-29 to 2013-12-20. These data include depth, dissolved Oxygen, dissolved organic Carbon, salinity calculated from CTD primary sensors, water pressure, and water temperature. The instruments used to collect these data include CTD Sea-Bird SBE 911plus, GO-FLO Bottle, and Niskin bottle. These data were collected by Gregory Cutter of Old Dominion University, James W. Moffett of University of Southern California, and Christopher R. German of Woods Hole Oceanographic Institution as part of the "U.S. GEOTRACES East Pacific Zonal Transect (U.S. GEOTRACES EPZT)" project and "U.S. GEOTRACES (U.S. GEOTRACES)" program. The Biological and Chemical Oceanography Data Management Office (BCO-DMO) submitted these data to NCEI on 2023-01-23.
The following is the text of the dataset description provided by BCO-DMO:
CTD - ODF Bottle
Dataset Description:
CTD bottle data from 30-ODF (Ocean Data Facility 12 bottle, 30 liter Niskin rosette) EPZT Transect. TEI columns are incomplete. Refer to separate TEI datasets from GEOTRACES EPZT for those values.
ODF CTD BOTTLE 20141030ODF
Note: 'FLAG_W' columns = WHP (WOCE Hydrographic Program) quality flags.
The following is the text of the dataset description provided by BCO-DMO:
CTD - ODF Bottle
Dataset Description:
CTD bottle data from 30-ODF (Ocean Data Facility 12 bottle, 30 liter Niskin rosette) EPZT Transect. TEI columns are incomplete. Refer to separate TEI datasets from GEOTRACES EPZT for those values.
ODF CTD BOTTLE 20141030ODF
Note: 'FLAG_W' columns = WHP (WOCE Hydrographic Program) quality flags.
Dataset Citation
- Cite as: Moffett, James W.; Cutter, Gregory A.; German, Christopher R. (2023). ODF bottle data along the US GEOTRACES East Pacific Zonal Transect from the R/V Thomas G. Thompson TN303 cruise in the tropical Pacific from Peru to Tahiti during 2013 (U.S. GEOTRACES EPZT project) (NCEI Accession 0277287). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://www.ncei.noaa.gov/archive/accession/0277287. Accessed [date].
Dataset Identifiers
ISO 19115-2 Metadata
gov.noaa.nodc:0277287
Download Data |
|
Distribution Formats |
|
Ordering Instructions | Contact NCEI for other distribution options and instructions. |
Distributor |
NOAA National Centers for Environmental Information +1-301-713-3277 NCEI.Info@noaa.gov |
Dataset Point of Contact |
NOAA National Centers for Environmental Information ncei.info@noaa.gov |
Time Period | 2013-10-29 to 2013-12-20 |
Spatial Bounding Box Coordinates |
West: -152.079
East: -77.376
South: -17.573
North: -10.224
|
Spatial Coverage Map |
General Documentation |
|
Associated Resources |
|
Publication Dates |
|
Data Presentation Form | Digital table - digital representation of facts or figures systematically displayed, especially in columns |
Dataset Progress Status | Complete - production of the data has been completed Historical archive - data has been stored in an offline storage facility |
Data Update Frequency | As needed |
Supplemental Information | Acquisition Description: From the TN303 cruise report: Two types of rosette/SBE9plus CTD casts (ODF/30L-Niskin and GT-C/12L-GoFlo) were made at 36 station locations during U.S. GEOTRACES EPZT. Deep ODF/30L-Niskin casts included a device suspended 20 meters below the rosette, designed either to take a core sample or pick up particulates from the sea floor. ODF/30L-Niskin Rosette/CTD casts were performed with a package consisting of a 12-bottle rosette frame (SIO/STS), a 12- or 24-place carousel (SBE32) and 12 ea. 30L General Oceanics Niskin-style bottles with an absolute volume of 30L each. A 12-place carousel was used on station 1, but had repeated trip-confirmation failures during stations 2 and 3. It was replaced with an older 24-place carousel mid-station 3, which resolved the trip-confirmation issues. Prior to station 4, the carousel head was replaced by one with titanium instead of stainless steel latches in order to resolve mechanical tripping issues. This "hybrid" carousel was used successfully for the remainder of the cruise. Underwater electronic components consisted of a Sea-Bird Electronics CTD (SBE9plus) with dual pumps (SBE5), dual temperature (SBE3plus), reference temperature (SBE35RT), dual conductivity (SBE4C), dissolved oxygen (SBE43), transmissometer (WET Labs C-Star), fluorometer (Seapoint SCF), Oxidation Reduction Potention (ORP) sensor (NOAA), turbidity meter (Seapoint STM11) and altimeter (Simrad 807). A second dissolved oxygen + oxygen temperature sensor (JFE Advantech RINKO-III) was incorporated into the data stream for future sensor evaluation; it was not processed for this cruise. Additionally, an SBE19plus CTD was mounted on the rosette during deep ODF casts for full and super stations beginning with station 25, since it could no longer be deployed on deep McLane pump casts after their wire was damaged. Shipboard CTD data processing was performed automatically at the end of each deployment using SIO/STS CTD processing software v.5.1.6-1. Raw GT-C CTD data and bottle trip files, acquired by SBE Seasave V 7.17a on a Windows XP workstation, were also imported into the Linux processing system, providing a backup of the raw data. Pre-cruise laboratory calibrations were applied, then CTD data were processed into a 0.5-second time series, bottle trips were extracted, and a 1-decibar down-cast pressure series of the data was created. The pressure-series data were used by the web service for interactive plots, sections and CTD data distribution. Time-series data, and eventually basic up-cast pressure-series data, were also available for distribution through the website. SIO/ODF CTD data were examined at the completion of each deployment for clean, corrected sensor response and any calibration shifts. As bottle salinity and oxygen results became available, they were used to refine shipboard conductivity and oxygen sensor calibrations. |
Purpose | This dataset is available to the public for a wide variety of uses including scientific research and analysis. |
Use Limitations |
|
Dataset Citation |
|
Cited Authors | |
Principal Investigators | |
Contributors | |
Resource Providers | |
Points of Contact | |
Publishers | |
Acknowledgments |
|
Use Constraints |
|
Data License | |
Access Constraints |
|
Fees |
|
Lineage information for: dataset | |
---|---|
Processing Steps |
|
Output Datasets |
|
Acquisition Information (collection) | |
---|---|
Instrument |
|
Platform |
|
Last Modified: 2024-05-31T18:50:46Z
For questions about the information on this page, please email: ncei.info@noaa.gov