Moored time-series records for chlorophyll and turbidity collected from the LB1 Mooring, LB2 Mooring, LB3 Mooring in the South Atlantic Bight (SAB) continental shelf off Long Bay from 2011-2012 (Long Bay Wintertime Bloom project) (NCEI Accession 0277270)
This dataset contains biological and physical data collected on LB1 Mooring, LB2 Mooring, and LB3 Mooring during deployments LB_2012_LB1, LB_2012_LB2, and LB_2012_LB3 in the North Atlantic Ocean from 2011-12-14 to 2012-04-04. These data include chlorophyll a, depth nominal, and turbidity. The instruments used to collect these data include WETLabs ECO-FLNTU. These data were collected by Catherine Edwards and Dr James Nelson of Skidaway Institute of Oceanography and Dr Harvey E. Seim of University of North Carolina at Chapel Hill as part of the "Mechanisms of nutrient input at the shelf margin supporting persistent winter phytoplankton blooms downstream of the Charleston Bump (Long Bay Wintertime Bloom)" project. The Biological and Chemical Oceanography Data Management Office (BCO-DMO) submitted these data to NCEI on 2023-01-23.
The following is the text of the dataset description provided by BCO-DMO:
Moored time-series records for chlorophyll and turbidity
Dataset Description:
Acquisition Description:
Mooring data records for optical sensors:
LB_2012_LB1 mooring (30 m depth) : Three ECO units were deployed, one on the bottom mooring frame (S/N 738) about 0.5 m above bottom, and two on a taut-line mooring attached to the frame, nominally at 15 m depth (S/N. 736) and 5 m depth (S/N 735). Sampling for the three LB1 ECO units was three consecutive 1-second readings at 6-minute (360 second) intervals. LB_2012_LB2 mooring (76 m depth) : One ECO unit was deployed on the ADCP mooring frame about 0.5 m above bottom (S/N 739). This unit had an apparent electronic failure during the deployment which resulted in a distinct positive baseline shift for turbidity and negative baseline shift for chlorophyll. The data record was considered suspect at this point and only data from the initial deployment period (before the baseline shift) is reported. Sampling for the LB2 unit was three consecutive 1 second readings at 6-minute (360 second) intervals. LB_2012_LB3 mooring (171 m depth) : The ECO unit (S/N 740) was mounted about 0.5 m above the bottom on the lower portion of the Floatation Technologies AL-200 Trawl Resistant Bottom Mount frame which held a 150 kHz ADCP unit. Due to the longer deployment period for the LB3 instrument and internal memory limitations, sampling was set for a single 1-second sample at 6-minute (360 second) intervals (instead of three 1-sec samples for the ECO units at LB1 and LB2).
Instrument calibrations and inter-comparisons: Manufacturer supplied calibration factors for chlorophyll concentration and turbidity were employed following pre- and post-deployment checks for consistency. The five ECO FLNTUSB units were serviced at WET Labs and calibrated as a set in May, 2011. Instrument inter-calibrations and the factory chlorophyll calibration factors were checked by obtaining a concurrent set of measurements in the water column before deployment. All ECO units were mounted on a piece of angle iron that was hung on a weighted line at the same depth as the ship’s CTD/carousel system (20 m below the surface at the shelf break station LB2 to avoid surface irradiance effects on the chlorophyll fluorescence signal). The units were held at depth for 5 minutes (acquiring 4-5 readings). Niskin bottle water samples were collected about mid-point of the sampling period for chlorophyll analyses (triplicate filtered samples frozen and stored in liquid nitrogen on the ship, analyzed in the shore lab by the fluorometric method). After recovery of the moorings, the units were photographed to record bio-fouling. The four functioning ECO units (except for S/N 739) were then mounted on the ship’s CTD/carousel frame for a post-deployment set of inter-comparison measurements at two depths in the water column (35 m and 10 m), again with Niskin samples collected for chlorophyll analyses. For chlorophyll estimated from fluorescence, the pre- and post-deployment readings showed agreement to within 0.1-0.15 mg/m 3 for readings at a measured concentration of 0.4 mg/mg 3 (both pre- and post-deployment) and 0.2 mg/m 3 at a measured concentration of 1.25 mg/m 3 . For turbidity the pre-deployment check showed close agreement between all units (average 0.066 +/- 0.002 NTU at 20 m depth). The post-deployment check appeared to be compromised by drying of a film on the optical windows after recovery prior to the post-deployment checks. For the turbidity data records, baseline readings over the deployment periods (minimum values) only showed marked increase for S/N 738 deployed on the mooring frame at LB1 (increasing from about 0.4 to 1.2 NTU during the latter part of the deployment). For the data reported here, there has been no correction for the apparent increase in baseline readings for this instrument.
Wetlabs calibration sheets : See Supplemental Files
Internal Clock Drift : Time was recorded as UTC with internal clocks set to a common GPS-based reference during the pre-deployment set-up. Internal clock drift during deployments was checked against the reference after recovery. Temporal offsets at recovery ranged from -9 seconds to +528 seconds with an average offset of +359 seconds (or about the sampling interval of 360 seconds). Given that most events in the optical records occurred on time scales of hours to days, no clock drift correction was applied. Time stamps in raw files in the format MM/DD/YY HH:MM:SS were converted to the Microsoft Excel epoch convention (01/01/1900 = 1) and to the Matlab serial date number format (01/01/0000 = 1) for Excel and Matlab files respectively.
The following is the text of the dataset description provided by BCO-DMO:
Moored time-series records for chlorophyll and turbidity
Dataset Description:
Acquisition Description:
Mooring data records for optical sensors:
LB_2012_LB1 mooring (30 m depth) : Three ECO units were deployed, one on the bottom mooring frame (S/N 738) about 0.5 m above bottom, and two on a taut-line mooring attached to the frame, nominally at 15 m depth (S/N. 736) and 5 m depth (S/N 735). Sampling for the three LB1 ECO units was three consecutive 1-second readings at 6-minute (360 second) intervals. LB_2012_LB2 mooring (76 m depth) : One ECO unit was deployed on the ADCP mooring frame about 0.5 m above bottom (S/N 739). This unit had an apparent electronic failure during the deployment which resulted in a distinct positive baseline shift for turbidity and negative baseline shift for chlorophyll. The data record was considered suspect at this point and only data from the initial deployment period (before the baseline shift) is reported. Sampling for the LB2 unit was three consecutive 1 second readings at 6-minute (360 second) intervals. LB_2012_LB3 mooring (171 m depth) : The ECO unit (S/N 740) was mounted about 0.5 m above the bottom on the lower portion of the Floatation Technologies AL-200 Trawl Resistant Bottom Mount frame which held a 150 kHz ADCP unit. Due to the longer deployment period for the LB3 instrument and internal memory limitations, sampling was set for a single 1-second sample at 6-minute (360 second) intervals (instead of three 1-sec samples for the ECO units at LB1 and LB2).
Instrument calibrations and inter-comparisons: Manufacturer supplied calibration factors for chlorophyll concentration and turbidity were employed following pre- and post-deployment checks for consistency. The five ECO FLNTUSB units were serviced at WET Labs and calibrated as a set in May, 2011. Instrument inter-calibrations and the factory chlorophyll calibration factors were checked by obtaining a concurrent set of measurements in the water column before deployment. All ECO units were mounted on a piece of angle iron that was hung on a weighted line at the same depth as the ship’s CTD/carousel system (20 m below the surface at the shelf break station LB2 to avoid surface irradiance effects on the chlorophyll fluorescence signal). The units were held at depth for 5 minutes (acquiring 4-5 readings). Niskin bottle water samples were collected about mid-point of the sampling period for chlorophyll analyses (triplicate filtered samples frozen and stored in liquid nitrogen on the ship, analyzed in the shore lab by the fluorometric method). After recovery of the moorings, the units were photographed to record bio-fouling. The four functioning ECO units (except for S/N 739) were then mounted on the ship’s CTD/carousel frame for a post-deployment set of inter-comparison measurements at two depths in the water column (35 m and 10 m), again with Niskin samples collected for chlorophyll analyses. For chlorophyll estimated from fluorescence, the pre- and post-deployment readings showed agreement to within 0.1-0.15 mg/m 3 for readings at a measured concentration of 0.4 mg/mg 3 (both pre- and post-deployment) and 0.2 mg/m 3 at a measured concentration of 1.25 mg/m 3 . For turbidity the pre-deployment check showed close agreement between all units (average 0.066 +/- 0.002 NTU at 20 m depth). The post-deployment check appeared to be compromised by drying of a film on the optical windows after recovery prior to the post-deployment checks. For the turbidity data records, baseline readings over the deployment periods (minimum values) only showed marked increase for S/N 738 deployed on the mooring frame at LB1 (increasing from about 0.4 to 1.2 NTU during the latter part of the deployment). For the data reported here, there has been no correction for the apparent increase in baseline readings for this instrument.
Wetlabs calibration sheets : See Supplemental Files
Internal Clock Drift : Time was recorded as UTC with internal clocks set to a common GPS-based reference during the pre-deployment set-up. Internal clock drift during deployments was checked against the reference after recovery. Temporal offsets at recovery ranged from -9 seconds to +528 seconds with an average offset of +359 seconds (or about the sampling interval of 360 seconds). Given that most events in the optical records occurred on time scales of hours to days, no clock drift correction was applied. Time stamps in raw files in the format MM/DD/YY HH:MM:SS were converted to the Microsoft Excel epoch convention (01/01/1900 = 1) and to the Matlab serial date number format (01/01/0000 = 1) for Excel and Matlab files respectively.
Dataset Citation
- Cite as: Nelson, James; Edwards, Catherine; Seim, Harvey E. (2023). Moored time-series records for chlorophyll and turbidity collected from the LB1 Mooring, LB2 Mooring, LB3 Mooring in the South Atlantic Bight (SAB) continental shelf off Long Bay from 2011-2012 (Long Bay Wintertime Bloom project) (NCEI Accession 0277270). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://www.ncei.noaa.gov/archive/accession/0277270. Accessed [date].
Dataset Identifiers
ISO 19115-2 Metadata
gov.noaa.nodc:0277270
Download Data |
|
Distribution Formats |
|
Ordering Instructions | Contact NCEI for other distribution options and instructions. |
Distributor |
NOAA National Centers for Environmental Information +1-301-713-3277 NCEI.Info@noaa.gov |
Dataset Point of Contact |
NOAA National Centers for Environmental Information ncei.info@noaa.gov |
Time Period | 2011-12-14 to 2012-04-04 |
Spatial Bounding Box Coordinates |
West: -78.33
East: -78.013
South: 32.852
North: 33.173
|
Spatial Coverage Map |
General Documentation |
|
Associated Resources |
|
Publication Dates |
|
Data Presentation Form | Digital table - digital representation of facts or figures systematically displayed, especially in columns |
Dataset Progress Status | Complete - production of the data has been completed Historical archive - data has been stored in an offline storage facility |
Data Update Frequency | As needed |
Purpose | This dataset is available to the public for a wide variety of uses including scientific research and analysis. |
Use Limitations |
|
Dataset Citation |
|
Cited Authors | |
Principal Investigators | |
Contributors | |
Resource Providers | |
Points of Contact | |
Publishers | |
Acknowledgments |
|
Theme keywords |
NODC DATA TYPES THESAURUS
NODC OBSERVATION TYPES THESAURUS
WMO_CategoryCode
|
Data Center keywords | NODC COLLECTING INSTITUTION NAMES THESAURUS NODC SUBMITTING INSTITUTION NAMES THESAURUS Global Change Master Directory (GCMD) Data Center Keywords |
Platform keywords | BCO-DMO Platform Names Global Change Master Directory (GCMD) Platform Keywords |
Instrument keywords | NODC INSTRUMENT TYPES THESAURUS BCO-DMO Standard Instruments Global Change Master Directory (GCMD) Instrument Keywords Originator Instrument Names |
Place keywords | NODC SEA AREA NAMES THESAURUS Global Change Master Directory (GCMD) Location Keywords Provider Place Names |
Project keywords | BCO-DMO Standard Projects Provider Deployment IDs Provider Funding Award Information |
Keywords | NCEI ACCESSION NUMBER |
Use Constraints |
|
Data License | |
Access Constraints |
|
Fees |
|
Lineage information for: dataset | |
---|---|
Processing Steps |
|
Output Datasets |
|
Acquisition Information (collection) | |
---|---|
Instrument |
|
Last Modified: 2024-05-31T15:15:28Z
For questions about the information on this page, please email: ncei.info@noaa.gov
For questions about the information on this page, please email: ncei.info@noaa.gov