Skip to main content
Dataset Overview | National Centers for Environmental Information (NCEI)

Dissolved inorganic carbon (DIC), total alkalinity, pH on the total scale, water temperature, salinity and other measurements collected from discrete samples and profile observations during the CCGS Hudson, R/V Coriolis II, CCGS Teleost, RRS James Cook and Fugro Discovery Atlantic Zone Monitoring Program cruises in the North Atlantic Ocean and Labrador Sea from 2014-11-16 to 2020-12-01 (NCEI Accession 0225518)

browse graphicPreview graphic
This dataset includes discrete sample and profile data collected during the CCGS Hudson, R/V Coriolis II, CCGS Teleost, RRS James Cook and Fugro Discovery Atlantic Zone Monitoring Program cruises in the North Atlantic Ocean and Labrador Sea from 2014-11-16 to 2020-12-01. These data include water temperature, salinity, dissolved oxygen, nutrients, dissolved inorganic carbon (DIC), total alkalinity, pH on the total scale, and ammonium. The Atlantic Zone Monitoring Program (AZMP) was implemented in 1998 with the aim of increasing Fisheries and Oceans Canada's (DFO) capacity to understand; describe; and forecast the state of the marine ecosystem and to quantify the changes in the ocean physical; chemical and biological properties. Ocean acidification is an emerging priority for Fisheries and Oceans Canada under the Aquatic Climate Change Adaption Services Program and is developing the knowledge-base necessary to support the development of adaptation tools and strategies and investing in science to better understand the specific consequences of a changing climate. Specifically; the effects of ocean acidification on ecosystems in the Northwest Atlantic and large aquatic basin risk assessments consider ocean acidification at the basin and sub-basin scale are being investigated.
  • Cite as: Colbourne, Eugene; Azetsu-Scott, Kumiko; Pepin, Pierre; Snook, Stephen; Maillet, Gary; Cyr, Frédéric; Lewis, Sara; Bishop, Charlie (2021). Dissolved inorganic carbon (DIC), total alkalinity, pH on the total scale, water temperature, salinity and other measurements collected from discrete samples and profile observations during the CCGS Hudson, R/V Coriolis II, CCGS Teleost, RRS James Cook and Fugro Discovery Atlantic Zone Monitoring Program cruises in the North Atlantic Ocean and Labrador Sea from 2014-11-16 to 2020-12-01 (NCEI Accession 0225518). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.25921/c981-4a58. Accessed [date].
gov.noaa.nodc:0225518
Download Data
  • HTTPS (download)
    Navigate directly to the URL for data access and direct download.
  • FTP (download)
    These data are available through the File Transfer Protocol (FTP). FTP is no longer supported by most internet browsers. You may copy and paste the FTP link to the data into an FTP client (e.g., FileZilla or WinSCP).
Distribution Formats
  • Originator data format
Ordering Instructions Contact NCEI for other distribution options and instructions.
Distributor NOAA National Centers for Environmental Information
+1-301-713-3277
NCEI.Info@noaa.gov
Dataset Point of Contact NOAA National Centers for Environmental Information
ncei.info@noaa.gov
Time Period 2014-11-16 to 2020-12-01
Spatial Bounding Box Coordinates
West: -61.3
East: -43
South: 49.27
North: 54.88
Spatial Coverage Map
General Documentation
Associated Resources
Publication Dates
  • publication: 2021-02-19
  • revision: 2021-10-29
Data Presentation Form Digital table - digital representation of facts or figures systematically displayed, especially in columns
Dataset Progress Status Complete - production of the data has been completed
Historical archive - data has been stored in an offline storage facility
Data Update Frequency As needed
Supplemental Information
In this accession, NCEI has archived multiple versions of these data. The latest (and best) version of these data has the largest version number.
Purpose A critical element of the AZMP involves an observation program aimed at assessing the variability in nutrients; phytoplankton and zooplankton. The overall aim is to identify fundamental relationships among elements of the planktonic ecosystem and establish how they respond to changes in environmental drivers(i). The AZMP derives its information on the state of the marine ecosystem from data collected at a network of sampling locations (high frequency sampling stations; cross-shelf sections; and groundfish surveys) in each region (Quebec; Gulf; Maritimes; NL) sampled at a frequency of biweekly to once annually.
Use Limitations
  • accessLevel: Public
  • Distribution liability: NOAA and NCEI make no warranty, expressed or implied, regarding these data, nor does the fact of distribution constitute such a warranty. NOAA and NCEI cannot assume liability for any damages caused by any errors or omissions in these data. If appropriate, NCEI can only certify that the data it distributes are an authentic copy of the records that were accepted for inclusion in the NCEI archives.
Dataset Citation
  • Cite as: Colbourne, Eugene; Azetsu-Scott, Kumiko; Pepin, Pierre; Snook, Stephen; Maillet, Gary; Cyr, Frédéric; Lewis, Sara; Bishop, Charlie (2021). Dissolved inorganic carbon (DIC), total alkalinity, pH on the total scale, water temperature, salinity and other measurements collected from discrete samples and profile observations during the CCGS Hudson, R/V Coriolis II, CCGS Teleost, RRS James Cook and Fugro Discovery Atlantic Zone Monitoring Program cruises in the North Atlantic Ocean and Labrador Sea from 2014-11-16 to 2020-12-01 (NCEI Accession 0225518). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.25921/c981-4a58. Accessed [date].
Cited Authors
Principal Investigators
Contributors
Resource Providers
Publishers
Acknowledgments
  • Funding Information: Government of Canada: Fisheries and Oceans Canada (Aquatic Climate Change Adaptation Services Program (ACCASP), 96036-881-15K)
Theme keywords NODC DATA TYPES THESAURUS NODC OBSERVATION TYPES THESAURUS WMO_CategoryCode
  • oceanography
Global Change Master Directory (GCMD) Science Keywords OCADS Study Type
  • Discrete measurement
Provider Variable Abbreviations
  • AMMONIUM
  • BEAM_CP
  • CHLA
  • CTDOXY
  • CTDPRS
  • CTDSAL_PSS78
  • CTDTMP_ITS90
  • CTD_PH_INSITU
  • DIC
  • NITRATE_NITRITE
  • PAR
  • PCO2_CALC_INSITU
  • PHOSPHATE
  • POC
  • PON
  • SIGMATHETA
  • SILICATE
  • TA
  • TA_CALC
  • pCO2
  • pH_25
Data Center keywords NODC COLLECTING INSTITUTION NAMES THESAURUS NODC SUBMITTING INSTITUTION NAMES THESAURUS Global Change Master Directory (GCMD) Data Center Keywords
Platform keywords NODC PLATFORM NAMES THESAURUS Global Change Master Directory (GCMD) Platform Keywords ICES/SeaDataNet Ship Codes
Instrument keywords NODC INSTRUMENT TYPES THESAURUS Global Change Master Directory (GCMD) Instrument Keywords
Place keywords NODC SEA AREA NAMES THESAURUS Global Change Master Directory (GCMD) Location Keywords Provider Geographic Names
  • Labrador Sea
  • North Atlantic Ocean
Project keywords NODC PROJECT NAMES THESAURUS Cruise ID
  • 15009
  • 15011
  • 20114
  • 20115
  • 20116
  • 20118
  • 20120
  • 39144
  • 39148
  • 39157
  • 39159
  • 39160
  • 39185
  • 39197
  • 39200
  • 39210
  • 79001
  • TEL173
  • TEL176
EXPOCODE
  • 18HU20141116
  • 18HU20151115
  • 18HU20161113
  • 18HU20181111
  • 18HU20201110
  • 18OL20180715
  • 18TL20150410
  • 18TL20150709
  • 18TL20160401
  • 18TL20160511
  • 18TL20160708
  • 18TL20170406
  • 18TL20170708
  • 18TL20180406
  • 18TL20190412
  • 18TL20190627
  • 18TL20200714
  • 740H20191117
  • PADS20171111
Ocean Acidification Search Keywords
  • Ocean Carbon and Acidification Data System (OCADS) Project
Reference Section ID
  • Atlantic Zone Monitoring Program
Research Projects
  • Atlantic Zone Monitoring Program
Keywords NCEI ACCESSION NUMBER
Use Constraints
  • Cite as: Colbourne, Eugene; Azetsu-Scott, Kumiko; Pepin, Pierre; Snook, Stephen; Maillet, Gary; Cyr, Frédéric; Lewis, Sara; Bishop, Charlie (2021). Dissolved inorganic carbon (DIC), total alkalinity, pH on the total scale, water temperature, salinity and other measurements collected from discrete samples and profile observations during the CCGS Hudson, R/V Coriolis II, CCGS Teleost, RRS James Cook and Fugro Discovery Atlantic Zone Monitoring Program cruises in the North Atlantic Ocean and Labrador Sea from 2014-11-16 to 2020-12-01 (NCEI Accession 0225518). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.25921/c981-4a58. Accessed [date].
Access Constraints
  • Use liability: NOAA and NCEI cannot provide any warranty as to the accuracy, reliability, or completeness of furnished data. Users assume responsibility to determine the usability of these data. The user is responsible for the results of any application of this data for other than its intended purpose.
Fees
  • In most cases, electronic downloads of the data are free. However, fees may apply for custom orders, data certifications, copies of analog materials, and data distribution on physical media.
Lineage information for: dataset
Processing Steps
  • 2021-02-19T09:40:14Z - NCEI Accession 0225518 v1.1 was published.
  • 2021-10-29T21:31:28Z - NCEI Accession 0225518 was revised and v2.2 was published.
    Rationale: Updates were received for this dataset. These updates were copied into the data/0-data/ directory of this accession. These updates may provide additional files or replace obsolete files. This version contains the most complete and up-to-date representation of this archival information package. All of the files received prior to this update are available in the preceding version of this accession.
Output Datasets
Lineage information for: dataset
Processing Steps
  • Parameter or Variable: Dissolved Inorganic Carbon; Abbreviation: DIC; Unit: umol / kg; Observation type: profile; Measured or calculated: measured; Sampling instrument: SeaBird Scientific 9plus CTD-Rosette system; Analyzing instrument: SOMMA seawater sample handling system with UIC 5011 coulometer; Detailed sampling and analyzing information: Seawater samples were collected at standard depths (5 mL seawater removed to allow for thermal expansion of seawater) and preserved within 30 minutes of collection with saturated solution of mercuric chloride; bottles were sealed with Apiezon M grease and ground glass stoppers were held in place with rubber band and banding clip and held in storage until transfer back to shore based facility for processing. All laboratory analyses were conducted at 25 degrees Celsius.; Replicate information: Single sample of 500 mL seawater from each standard depth; Standardization description: Calculate average offset based on at least one or more certified reference standards daily and offset correction applied to measured value; Standardization frequency: Daily during processing; CRM manufacturer: Andrew Dickson's Lab at Scripps Institute of Oceanography (co2crms@ucsd.edu); CRM batch number: Batch 139; Preservation method: saturated solution of mercuric chloride; Preservative volume: 100 uL (0.02 % by volume); Preservative correction: 0.02 % correction is applied by multiplying correction factor of 1.0002 to CRM-corrected data; Uncertainty: Assessed by computing the average standard deviation of duplicate water samples; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: Dickson; A.G.; Sabine; C.L. and Christian; J.R. (Eds.) 2007. Guide to Best Practices for Ocean CO2 Measurements. PICES Special Publication 3; 191 pp.; https://cdiac.ess-dive.lbl.gov/ftp/oceans/Handbook_2007/Guide_all_in_one.pdf; Researcher name: Kumiko Azetsu-Scott; Researcher institution: Bedford Institute of Oceanography.
  • Parameter or Variable: Total alkalinity; Abbreviation: TA; Unit: umol / kg; Observation type: profile; Measured or calculated: measured; Sampling instrument: SeaBird Scientific 9plus CTD-Rosette system; Analyzing instrument: Automated sample handling system (Bedford Institute of Oceanography); Metrohm Titrando dosing instrument controlled by computer with Metrohm Tiamo software interfaced to an LL Aquatrode glass electrode. Sample maintained at 25 degrees C in a water jacketed cell.; Type of titration: Multi-point potentiometric titration with initial aliquot of HCl to acidify sample.; Cell type (open or closed): Open cell titration; Curve fitting method: Modifed GRAN plot used as input parameters for non-linear curve fitting on titration data and sample parameters (sample weight; acid density; acid concentration) and density calculated from salinity.; Detailed sampling and analyzing information: Seawater samples were collected at standard depths (5 mL seawater removed to allow for thermal expansion of seawater) and preserved within 30 minutes of collection with saturated solution of mercuric chloride; bottles were sealed with Apiezon M grease and ground glass stoppers were held in place with rubber band and banding clip and held in storage until transfer back to shore based facility for processing. All laboratory analyses were conducted at 25 degrees Celsius.; Replicate information: Single sample of 500 mL seawater from each standard depth; Standardization description: Calculate average offset based on at least one or more certified reference standards daily and offset correction applied to measured value; Standardization frequency: Daily during processing; CRM manufacturer: Andrew Dickson's Lab at Scripps Institute of Oceanography; CRM batch number: Batch 139; Preservation method: saturated solution of mercuric chloride; Preservative volume: 100 uL (0.02 % by volume); Preservative correction: 0.02 % correction is applied by multiplying correction factor of 1.0002 to CRM-corrected data; TA blank correction: Averages between 10-40 umol / kg; Uncertainty: Assessed by computing the average standard deviation of duplicate water samples; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: Dickson; A.G.; Sabine; C.L. and Christian; J.R. (Eds.) 2007. Guide to Best Practices for Ocean CO2 Measurements. PICES Special Publication 3; 191 pp.; https://cdiac.ess-dive.lbl.gov/ftp/oceans/Handbook_2007/Guide_all_in_one.pdf; Researcher name: Kumiko Azetsu-Scott; Researcher institution: Bedford Institute of Oceanography.
  • Parameter or Variable: pH; Abbreviation: pH_25; pH scale: Total scale; Observation type: profile; Measured or calculated: measured; Sampling instrument: SeaBird Scientific 9plus CTD-Rosette system; Analyzing instrument: Agilent 8353 spectrophotometer; Temperature of pH measurement: 25 degrees C; Detailed sampling and analyzing information: Seawater samples collected in borosilicate glass bottles. Bottles were equilibrated to 25 degrees C then samples transferred into temperature controlled 10 cm quartz cell. Purified m-cresol purple was added and the cell shaken to mix the dye solution. Absorbances measured at 434; 578 and 730 nm.; Standardization description: Measurement of Batch 139 CO2 CRMs (Andrew Dickson) where pH at 25 degrees C was calculated using CO2.SYS software; Standardization frequency: Twice per day (to bracket sample set); pH standard values: Variable depending on CRM batch; Temperature of standardization: 25 degrees C; At what temperature was pH reported: 25 degrees C; Uncertainty: Typically 0.003; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: SOP 6b; Dickson; AG; Sabine; CL and Cristian; JR (Eds.) 2007. Guide to best practices for ocean CO2 measurement.; Researcher name: Kumiko Azetsu-Scott; Researcher institution: Bedford Institute of Oceanography.
  • Parameter or Variable: pCO2 (fCO2) discrete; Abbreviation: pCO2; Unit: uatm; Observation type: profile; Measured or calculated: measured; Sampling instrument: Ocean Test Equipment 5L Niskin Bottle; Analyzing instrument: SRI 8610C gas chromatograph with flame ionization detector and methanizer; Storage method: Vials stored in refrigerator; Seawater volume: 150 mL; Headspace volume: 11 mL; Temperature of measurement: 22 degrees Celcius; Detailed sampling and analyzing information: Seawater samples were collected in 160 mL volume crimp seal serum bottles; allowing the bottle to overflow by 3 volumes. The sample was immediately stabilised by the addition of 50 mL of saturated mercuric chloride solution; crimp sealed with a butyl rubber septum then stored in a refrigerator. Before analysis; a 11 mL headspace of 400 ppm CO2 in zero air was introduced into the bottle which was then thermally equilibrated at 22 °C for one hour. The bottle was then shaken vigorously for 8 minutes and the headspace displaced by a brine solution; flushing the sample loop of an SRI gas chromatograph equipped with a methaniser and flame ionisation detector. CO2 peaks were calibrated by injections of primary standard gas mixtures (Air Liquide) having CO2 mixing ratios of 397.3; 797.2; 1201 and 2017 ppm.; Gas detector manufacturer: SRI instruments; Gas detector model: 8610 GC-FID with methanizer; Gas detector resolution: 0.1 uatm; Gas detector uncertainty: 1 uatm; Standardization technique: Calibration plot made up from injections of primary gas standards; 400 ppm; 800 ppm; 1200 ppm; Standardization frequency: Twice daily; before and after each batch of samples; Temperature of standardization: Sample loop held at 40 degrees; Standard gas manufacturer: Air Liquide; Standard gas concentration: 397.3 ppm; 797.2 ppm; 1201 ppm; Standard gas uncertainty: 0.01; Water vapor correction method: Dickson et al.; 2007; Guide to best practices for ocean CO2 measurements; Sop 4; section 8.3; Temperature correction method: None; At what temperature was pCO2 reported: 22 degrees Celcius; Uncertainty: 0.0025; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: Dickson; A.G.; Sabine; C.L. and Christian; J.R. (Eds.) 2007. Guide to Best Practices for Ocean CO2 Measurements. PICES Special Publication 3; 191 pp.; https://cdiac.ess-dive.lbl.gov/ftp/oceans/Handbook_2007/Guide_all_in_one.pdf; Researcher name: Kumiko Azetsu-Scott; Researcher institution: Bedford Institute of Oceanography.
  • Parameter or Variable: pressure; Abbreviation: CTDPRS; Unit: decibars; Observation type: profile; Sampling instrument: SeaBird Scientific pressure sensor; SBE Digiquartz 6000 m pressure sensor; integrated in the 9plus CTD housing; Detailed sampling and analyzing information: SeaBird Scientific 9plus CTD-Rosette system; Replicate information: Primary and secondary sensors installed; Uncertainty: standard deviation calculated from dual pressure sensors; Quality flag convention: 1 = CTD not calibrated; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Interpolated over a pressure interval > 2dbar; 7 = Despiked; 8 = Bottle pair did not trip correctly; 9 = Not sampled; Method reference: https://www.seabird.com/profiling/sbe-911plus-ctd/family?productCategoryId=54627473769; Researcher name: Charlie Bishop; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: temperature; Abbreviation: CTDTMP_ITS90; Unit: degrees Celsius; Observation type: profile; Sampling instrument: SeaBird Scientific temperature sensor; Detailed sampling and analyzing information: Temperature sensors interfaced to a SeaBird Scientific 9plus CTD-Rosette system; Replicate information: Primary and secondary sensors installed; Uncertainty: standard deviation calculated from dual sensors; Quality flag convention: 1 = CTD not calibrated; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Interpolated over a pressure interval > 2dbar; 7 = Despiked; 8 = Bottle pair did not trip correctly; 9 = Not sampled; Method reference: https://www.seabird.com/profiling/sbe-911plus-ctd/family?productCategoryId=54627473769; Researcher name: Charlie Bishop; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: Total Alkalinity; Abbreviation: TA_CALC; Unit: umol / kg; Observation type: profile; Detailed sampling and analyzing information: Total alkalinity calculated based on non-linear estimation of TA versus salinity.; Uncertainty: Unknown; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Researcher name: Gary Maillet; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: salinity; Abbreviation: CTDSAL_PSS78; Unit: psu; Observation type: profile; Sampling instrument: SeaBird Scientific SBE4plus conductivity sensor; Detailed sampling and analyzing information: Conductivity sensors interfaced to a SeaBird Scientific 9plus CTD-Rosette system; Replicate information: Primary and secondary sensors installed; Uncertainty: standard deviation calculated from dual conductivity sensors; Quality flag convention: 1 = CTD not calibrated; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Interpolated over a pressure interval > 2dbar; 7 = Despiked; 8 = Bottle pair did not trip correctly; 9 = Not sampled; Method reference: https://www.seabird.com/profiling/sbe-911plus-ctd/family?productCategoryId=54627473769; Researcher name: Charlie Bishop; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: Density; Abbreviation: SIGMATHETA; Unit: Kg / m3; Observation type: profile; Detailed sampling and analyzing information: Seasoft V2: SBE Data Processing (09/12/2017 release date); Version 7.26.8; Uncertainty: Unknown; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: https://www.seabird.com/software; Researcher name: Charlie Bishop; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: dissolved oxygen; Abbreviation: CTDOXY; Unit: mL / L; Observation type: profile; Sampling instrument: SeaBird SBE 43 DO sensor; Detailed sampling and analyzing information: Discrete samples collected in duplicate and processed using Winkler titration to determine offsets against sensor values.; Uncertainty: standard deviation calculated from dual SBE 43 DO sensors and Winkler titrations; Quality flag convention: 1 = CTD not calibrated; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Interpolated over a pressure interval > 2dbar; 7 = Despiked; 8 = Bottle pair did not trip correctly; 9 = Not sampled; Method reference: http://www.dfo-mpo.gc.ca/Library/1507.pdf; Researcher name: Charlie Bishop; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: pH; Abbreviation: CTD_PH_INSITU; Unit: NBS scale; Observation type: profile; Sampling instrument: SeaBird Scientific pH sensor SBE-18; Detailed sampling and analyzing information: In-situ pH sensor profile data (NBS-scale; not calibrated) obtained from in-situ profiling with SeaBird Scientific 9plus SBE CTD; Uncertainty: unknown; Quality flag convention: 1 = CTD not calibrated; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Interpolated over a pressure interval > 2dbar; 7 = Despiked; 8 = Bottle pair did not trip correctly; 9 = Not sampled; Method reference: https://www.seabird.com/ph-sensors/sbe-18-ph-sensor/family?productCategoryId=54627869929; Researcher name: Charlie Bishop; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: Combined Nitrate and Nitrite; Abbreviation: NITRATE_NITRITE; Unit: mmol / m3; Observation type: Discrete; Sampling instrument: Ocean Test Equipment 5L Niskin Bottle; Analyzing instrument: Seal Analytical AAIII Autoanalyzer; Detailed sampling and analyzing information: Seawater samples were collected at standard depths and stored in 50 mL Falcon tubes and frozen at -20 degrees Celsius within 30 minutes of collection. Seawater samples were maintained frozen until analysis using Seal Analytical method No. G-172-96 R18 (Multitest MT 19).; Replicate information: Samples collected in duplicate from Niskin bottles; Uncertainty: Assessed by computing the standard deviation of sample duplicates; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: https://www.seal-analytical.com/Methods/AutoAnalyzerMethods/AutoAnalyzerMulti-testMethods/tabid/80/language/en-US/Default.aspx; Researcher name: Gary Maillet; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: Ammonia; Abbreviation: AMMONIUM; Unit: mmol / m3; Observation type: Discrete; Sampling instrument: Ocean Test Equipment 5L Niskin Bottle; Analyzing instrument: Seal Analytical AAIII Autoanalyzer interfaced with JASCO Fluorescence detector (FP-4025); Detailed sampling and analyzing information: Seawater samples were collected at standard depths and stored in 50 mL Falcon tubes and frozen at -20 degrees Celsius within 30 minutes of collection. Seawater samples were maintained frozen until analysis using Seal Analytical method No. G-327 R7 (Multitest MT 19).; Replicate information: Samples collected in duplicate from Niskin bottles; Uncertainty: Assessed by computing the standard deviation of sample duplicates; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: https://www.seal-analytical.com/Methods/AutoAnalyzerMethods/AutoAnalyzerMulti-testMethods/tabid/80/language/en-US/Default.aspx; Researcher name: Gary Maillet; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: Silicate; Abbreviation: SILICATE; Unit: mmol / m3; Observation type: Discrete; Sampling instrument: Ocean Test Equipment 5L Niskin Bottle; Analyzing instrument: Seal Analytical AAIII Autoanalyzer; Detailed sampling and analyzing information: Seawater samples were collected at standard depths and stored in 50 mL Falcon tubes and frozen at -20 degrees Celsius within 30 minutes of collection. Seawater samples were maintained frozen until analysis using Seal Analytical method No. G-297-03 Rev. 6 (Multitest MT 19).; Replicate information: Samples collected in duplicate from Niskin bottles; Uncertainty: Assessed by computing the standard deviation of sample duplicates; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: https://www.seal-analytical.com/Methods/AutoAnalyzerMethods/AutoAnalyzerMulti-testMethods/tabid/80/language/en-US/Default.aspx; Researcher name: Gary Maillet; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: Phosphate; Abbreviation: PHOSPHATE; Unit: mmol / m3; Observation type: Discrete; Sampling instrument: Ocean Test Equipment 5L Niskin Bottle; Analyzing instrument: Seal Analytical AAIII Autoanalyzer; Detailed sampling and analyzing information: Seawater samples were collected at standard depths and stored in 50 mL Falcon tubes and frozen at -20 degrees Celsius within 30 minutes of collection. Seawater samples were maintained frozen until analysis using Seal Analytical method No. G-297-03 Rev. 6 (Multitest MT 19).; Replicate information: Samples collected in duplicate from Niskin bottles; Uncertainty: Assessed by computing the standard deviation of sample duplicates; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: https://www.seal-analytical.com/Methods/AutoAnalyzerMethods/AutoAnalyzerMulti-testMethods/tabid/80/language/en-US/Default.aspx; Researcher name: Gary Maillet; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: Photosynthetic Active Radiation; Abbreviation: PAR; Unit: umol / s1 / m2; Observation type: profile; Sampling instrument: Satlantic PAR sensor ASY-PAR-00034; Uncertainty: unknown; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: https://www.seabird.com/multispectral-radiometers/photosynthetically-active-radiation-par-sensor/family?productCategoryId=54627869939; Researcher name: Charlie Bishop; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: Chlorophyll-a; Abbreviation: CHLA; Unit: mg / m3; Observation type: profile; Sampling instrument: Sea-Bird Scientific chlorophyll-a fluorometer ECO-FL-RTD; Analyzing instrument: Turner Designs 10AU Chlorophyll-a Fluorometer; Detailed sampling and analyzing information: Chlorophyll-a analysis using Welshmeyer 1994 non-acidification technique calibrated with Sigma-Aldrich standard C6144. When discrete chorophyll a was missing; calibrated chlorophyll-a fluorescence was substituted.; Uncertainty: standard deviation calculated from duplicate measurements of chlorophyll a pigment using fluorometry; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: https://aslopubs.onlinelibrary.wiley.com/doi/epdf/10.4319/lo.1994.39.8.1985; Researcher name: Gary Maillet; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: Particulate Organic Carbon; Abbreviation: POC; Unit: ug / L; Observation type: profile; Sampling instrument: SeaBird Scientific 9plus CTD-Rosette system; Analyzing instrument: Exeter Analytical CHNS (Model CE-440 interfaced to CE-490 Control Unit); Detailed sampling and analyzing information: 500 mL of seawater was filtered onto clean (baked at 450 C for 4 hours) GF/F glass fiber filters at each discrete depth; frozen at -20 °C; dried at 45 °C; pellitized and processed with CE440 Exeter CHNS.; Replicate information: 500 mL seawater samples collected in duplicate at each discrete depth; Uncertainty: Standard deviation of sample replicates; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: http://www.eai1.com/APP%2053.PDF; Researcher name: Gary Maillet; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: Particulate Organic Nitrogen; Abbreviation: PON; Unit: ug / L; Observation type: profile; Sampling instrument: SeaBird Scientific 9plus CTD-Rosette system; Analyzing instrument: Exeter Analytical CHNS (Model CE-440 interfaced to CE-490 Control Unit); Detailed sampling and analyzing information: 500 mL of seawater was filtered onto clean (baked at 450 C for 4 hours) GF/F glass fiber filters at each discrete depth; frozen at -20 °C; dried at 45 °C; pellitized and processed with CE440 Exeter CHNS.; Replicate information: 500 mL seawater samples collected in duplicate at each discrete depth; Uncertainty: Standard deviation of sample replicates; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: http://www.eai1.com/APP%2053.PDF; Researcher name: Gary Maillet; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: Beam Attenuation; Abbreviation: BEAM_CP; Unit: m-1; Observation type: profile; Sampling instrument: SeaBird Scientific C-STAR Transmissometer (CST-25-DR); Detailed sampling and analyzing information: Beam attenuation was computed from transmittance signals and calibration constant using standard formula provided by manufacturer; Uncertainty: unknown; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: https://www.seabird.com/transmissometers/c-star-transmissometer/family?productCategoryId=54627869913; Researcher name: Gary Maillet; Researcher institution: Northwest Atlantic Fisheries Centre.
  • Parameter or Variable: Calculated in-situ pCO2; Abbreviation: PCO2_CALC_INSITU; Unit: uatm; Observation type: profile; Detailed sampling and analyzing information: CO2Calc v4.0.9 (https://www.usgs.gov/software/co2calc); CO2 constant: K1; K2 from Hansson 1973; refit by Dickson and Millero 1987; pH scale: Total Scale; KHSO4: Dickson 1990; Total Boron: Lee et al.; 2010; Uncertainty: unknown; Quality flag convention: 1 = Sample drawn from bottle but analysis not recieved; 2 = QC Performed: Acceptable Measurement; 3 = QC Performed: Questionable Measurement; 4 = QC Performed: Bad Measurement; 5 = QC Performed: Not Reported; 6 = Mean of replicate measurements; 7 = Manual chromatographic peak measurement; 8 = Irregular digital chromatographic peak integration; 9 = Not sampled; Method reference: https://pubs.usgs.gov/of/2010/1280/; Researcher name: Gary Maillet; Researcher institution: Northwest Atlantic Fisheries Centre .
Acquisition Information (collection)
Instrument
  • carbon dioxide (CO2) gas analyzer
  • CTD
  • Niskin bottle
  • nutrient autoanalyzer
  • salinometer
  • temperature sensor
  • titrator
Platform
  • CCGS Teleost
  • CORIOLIS II
  • HUDSON
  • MV Fugro Discovery
  • RRS James Cook
Last Modified: 2024-06-10T13:16:30Z
For questions about the information on this page, please email: ncei.info@noaa.gov