The Ocean Archive System searches our original datasets as they were submitted to us, not individual points or profiles. If you want to search and retrieve ocean profiles in a common format, or objectively analyzed fields, your better option may be to use one of our project applications. See: Access Data

OAS accession Detail for 0278258
<< previous |revision: 1
accessions_id: 0278258 | archive
Title: Carbon export from San Dieguito Lagoon from samples for seawater carbonate biogeochemistry between April 2014 and January 2015 (NCEI Accession 0278258)
Abstract: This dataset contains chemical and physical data collected during deployment San_Dieguito_Lagoon_2014-15 from 2014-04-30 to 2015-01-24. These data include Ammonium, Nitrate, Nitrite, O2 saturation, Si, dissolved inorganic Carbon, reactive phosphorus (PO4), salinity calculated from CTD primary sensors, total alkalinity, total organic Carbon, and water temperature. The instruments used to collect these data include Automatic titrator, Inorganic Carbon Analyzers, Seal Analytical AutoAnalyser 3HR, Shimadzu TOC-V Analyzer, and Water Quality Multiprobe. These data were collected by Andreas Andersson of University of California-San Diego as part of the "CAREER: Biogeochemical Modification of Seawater CO2 Chemistry in Near-Shore Environments: Effect of Ocean Acidification (Nearshore CO2)" project. The Biological and Chemical Oceanography Data Management Office (BCO-DMO) submitted these data to NCEI on 2019-05-08.

The following is the text of the dataset description provided by BCO-DMO:

San Dieguito Lagoon Carbon export

Dataset Description:
General study design:
In this study, samples for seawater carbonate biogeochemistry were collected in the San Dieguito Lagoon (SDL) over the course of a year, both at the mouth of the lagoon during ebb tide and at stations spatially distributed across the lagoon at high tide. The study was designed to assess the lateral carbon flux from SDL to the coastal ocean, and how this changed under different environmental conditions.
Date received: 20190508
Start date: 20140430
End date: 20150124
Seanames:
West boundary: -117.267
East boundary: -117.119
North boundary: 33.063
South boundary: 32.968
Observation types:
Instrument types:
Datatypes:
Submitter:
Submitting institution: Biological and Chemical Oceanography Data Management Office
Collecting institutions:
Contributing projects:
Platforms:
Number of observations:
Supplementary information: Acquisition Description:
Methods description:
Between April 2014 and January 2015, discrete samples for total alkalinity (TA), dissolved inorganic carbon (DIC), total organic carbon (TOC), and nutrients (nitrate, nitrite, ammonium, phosphate, and silicate) were collected hourly from high tide to low tide at the mouth of SDL, both during the day and during the night. Samples for TA, DIC, and nutrients were also collected at ten different sites across the SDL during the day at high tide. For all samples collected, surface temperature, salinity, and dissolved oxygen were measured with handheld YSI multiprobe while discrete seawater samples were collected by hand at the surface following standard protocols.

Analytical Methods:
Surface seawater samples were collected by hand at ~0.25 m depth using 250 ml Pyrex glass bottles and immediately fixed with 100 µL HgCl2 as per standard protocols (Dickson et al. 2007). A handheld YSI multiprobe Pro2030 was calibrated and used to measure temperature, salinity, and dissolved oxygen saturation at the time of sampling. All seawater samples were transported to the Scripps Coastal and Open Ocean Biogeochemistry lab and analyzed for TA via an open-cell potentiometric acid titration system developed at Scripps Institution of Oceanography (SIO) by A. Dickson (Dickson et al. 2007) and DIC via an automated infra-red inorganic carbon analyzer (AIRICA, Marianda Inc). Nutrient samples were filtered through a 0.45 um filter into acid-leached HDPE-containers, and kept frozen until analysis. They were analyzed at Oceanographic Data Facility at SIO (http://odf.ucsd.edu ) using a Seal Analytical continuous-flow AutoAnalyzer. TOC samples were collected in combusted glass-vial and acidified with trace-metal grade HCl. They were analyzed in the Aluwihare lab at SIO according to Pedler et al. (2014) by combusting an unfiltered sample and measuring CO2 gas concentration using a non-dispersive infrared detector.

Quality Control:
Standard protocols were followed for sampling and analysis of seawater all parameters. The YSI multiprobe was calibrated prior to each sampling with an accuracy of ±0.2°C for temperature, ±0.3 g kg-1 for salinity, and ±2% for DO. The mean accuracy (TA±1 µmol kg-1, DIC ±1 µmol kg-1) and precision (TA±2 µmol kg-1, DIC ±2 µmol kg-1) of TA and DIC measurements were evaluated using certified reference materials (CRM) provided by the laboratory of A. Dickson at SIO and analyzed every 5 samples for DIC and ~10 samples for TA. The uncertainty of the nutrient measurements were reported as nitrate ±0.05 uM, nitrite ±0.05 uM, ammonium ±0.03 uM, silicate ±2-4 uM, and phosphate ±0.004 uM by ODF. The TOC method was reported with an uncertainty of ±5%.
Availability date:
Metadata version: 1
Keydate: 2023-05-15 04:51:32+00
Editdate: 2023-05-15 04:53:04+00